![Kobold OMH-15 Operating Instructions Manual Download Page 25](http://html1.mh-extra.com/html/kobold/omh-15/omh-15_operating-instructions-manual_1982498025.webp)
OMH
OMH K02/1122
page 25
16. Order Codes
Example:
OMH-15F154H 1 S4
Flow rate
[l/min]
Code
Process connection
Pmax
1)
[bar]
Pulses/l
2)
Frequency
2)
[Hz]
Gasket
Bearing
Pulse
generator
3)
0.1 - 10
OMH-15
R1500
= G½
420
2432
4.1 – 405
1
= FKM
S
= steel ball
bearing
4
= model 44
5
= model 45
F1532
= DN15/PN320
F154H
= DN15/PN400
400
0.3 - 30
OMH-20
R2000
= G¾
420
1280
6.4 – 640
F1532
= DN15/PN320
F154H
= DN15/PN400
400
1 - 100
OMH-25
R2500
= G1
420
468
7.4 – 780
F2532
= DN25/PN320
F254H
= DN25/PN400
400
3.5 - 350
OMH-40
R4000
= G1½
420
142
8.3 – 828
F4032
= DN40/PN320
F404H
= DN40/PN400
400
7 - 700
OMH-50
R5000
= G2
420
79.6
9.3 – 929
F501S
= DN50/PN160
F502F
= DN50/PN250
F5032
= DN50/PN320
F504H
= DN50/PN400
400
20 - 2000
OMH-1H
R1H00
= G4
250
33.6
11.2 - 1120
F1H64
= DN100/PN54
F1H1H
= DN100/PN100
F1H1S
= DN100/PN160
F1H2F
= DN100/PN250
1)
Please note limitations due to pulse generator and flange pressure rating.
2)
Pulse generator 45 has higher pulse/l and output frequency (for values see type plate and on request)
3)
Specifications see table „Technical Details Pulse Generators“.