Mounting:
This work should be done by competent per-
sonnel only. This instruction should be used as
support for this activity. If spindle set or meas-
uring casing will be replaced, volumeter must
be recalibrated!
mount o-rings
change of bearings:
mount circlips and spacers (for boring) on
pole wheel side.
press on rolling bearings
turning moments for the screws:
OMH-1H: large spindle 200 Nm
small spindle 49 Nm
OMH-1F: large spindle 200 Nm
small spindle 86 Nm
mount circlips and spacers on measuring spindles
mount groove nut with locking plate on small measuring spindle
(Fig.2)
mount spindle set into crown (with pick up) (Fig.1)
mount circlips on crown
mount pole wheel with spacer, feather, locking plate and
groove nut (Fig. 4)
mount measuring casing (Fig.3)
mount crown (with pick up) (Fig.5)
mount flange covers (Fig. 6)
tighten screws crosswise
install volumeter