17. EU Declaration of Conformance 

We, KOBOLD-Messring GmbH, Hofheim-Ts, Germany, declare under our sole 
responsibility that the product: 
 

KAL-K  Electronic Flow Monitor, 24 V

DC,

 110 V

AC/DC, 

 230 V

AC

 

 
to which this declaration relates is in conformity with the standards noted below:  
 

EN 61000-6-4:2011 

Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission 
standard for industrial environments 
 

EN 61000-6-2:2005 

Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for 
industrial environments 
 

EN 61010-1:2011 

Safety requirements for electrical equipment for measurement, control and 
laboratory use - Part 1: General requirements 
 
 
Also the following EC guidelines are fulfilled: 
 

2014/30/EU  

EMC 

Directive 

2014/35/EU

 

 

Low Voltage Directive 

2011/65/EU

 

 

RoHS

 (category 9) 

 
 

Hofheim, 12. May 2016 

 

 

H. Peters 

M. Wenzel 

 

General Manager 

Proxy Holder 

 
 

Summary of Contents for KAL-K

Page 1: ...Operating Instruction for Electronic Flow Monitor Compact Version Model KAL K...

Page 2: ...8 Characteristics 7 9 Output Characteristic only for 24 VDC 8 10 Commissioning 9 11 Maintenance 10 12 Technical Information 11 13 KAL K Diagnostics 12 14 Order Codes 12 15 Spare parts 12 16 Dimension...

Page 3: ...uld damage to a device be visible we recommend a thorough inspection of the delivery packaging In case of damage please inform your parcel service forwarding agent immediately since they are responsib...

Page 4: ...ss the pipe cross section and approaches zero at the pipe wall This means that in practice the depth of installation of the probe the internal pipe diameter and the flow profile of the liquid in the p...

Page 5: ...letely filled with fluid The mounting position has to be smooth and free of turbulence Recommended input and output length 5 x pipe diameter of straight run piping both upstream and downstream of the...

Page 6: ...ly voltage of 24 VDC 10 see 12 Technical Information Check function of electronic set point LED must flash Calibrate flow switch see 10 Commissioning 110 VDC 110 VAC or 230 VAC version Remove electron...

Page 7: ...tion mode If a calibration is done the bi coloured LED flashes green see also section 10 Commissioning If any signal error occurs the bi coloured LED flashes red SET pushbutton 3 The calibration switc...

Page 8: ...tput is GND GROUND 0 VDC Output function N O function In the N O function the output switches into the low resistance state PNP NPN DUO LED Actual value set point green Actual value set point red Brea...

Page 9: ...ays no flow The LED strip is not illuminated only the threshold value LED is flashing The Flow Monitor is ready for operation b Calibration of the trend indicator span The KAL K is factory checked and...

Page 10: ...t point Alarm status Bi coloured LED red Actual value 0 no flow present slowly flashing switching point LED set point Actual value set point Alarm status LED Bi coloured LED red Actual value Actual va...

Page 11: ...optical indication on LED chain with flashing LED Output indicator LED red alarm green flow OK Switching output 24 VDC version semiconductor PNP NPN switchable max 400 mA short circuit proof 110 VDC...

Page 12: ...KAL K1415 KAL K6415 G 3 4 KAL K1320 KAL K6320 KAL K1420 KAL K6420 M 12x1 KAL K0312 1 4 NPT KAL K5308 KAL K8308 KAL K5408 KAL K8408 1 2 NPT KAL K5315 KAL K8315 KAL K5415 KAL K8415 3 4 NPT KAL K5320 KAL...

Page 13: ...AL K 24VAC DC L D B L D O O O K B B K O D L O O D L K B O KAL K KAL A K A 1 4301 1 4305 1 4571 G 1 2 X X X 1 2 NPT X X G 1 4 X X G 3 4 X M 12x1 X X 1 4 NPT X X 3 4 NPT X X A C mm E mm F mm G mm G 26 7...

Page 14: ...KAL K Page 14 KAL K K03 0516 KAL 4440 with Tri clamp...

Page 15: ...patibility EMC Part 6 4 Generic standards Emission standard for industrial environments EN 61000 6 2 2005 Electromagnetic compatibility EMC Part 6 2 Generic standards Immunity for industrial environme...

Reviews: