Kobold KAL-D Operating Instructions Manual Download Page 14

KAL-D 

page 14 

 

KAL-D K03/0516 

16. EU Declaration of Conformance 

We, Kobold Messring GmbH, Hofheim-Ts, Germany, declare under our sole 
responsibility that the product: 
 
 

Compact Calorimetric Flow Monitor 

Model: KAL-D 

 
 
to which this declaration relates is in conformity with the standards noted below:  
 

EN 61000-6-4:2011 

Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission 
standard for industrial environments 

 
EN 61000-6-2:2005 

Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for 
industrial environments 
 
Also the following EC guidelines are fulfilled: 
 

2014/30/EU  

EMC 

Directive 

2011/65/EU

 

 

RoHS

 (category 9)  

 
 
 

Hofheim, 12. May 2016 

 

 

H. Peters 

M. Wenzel 

 

General Manager 

Proxy Holder 

 

Summary of Contents for KAL-D

Page 1: ...Operating Instructions for Compact Calorimetric Flow Monitor Model KAL D...

Page 2: ...dicators and Controls 7 9 Signal Output 8 9 1 Output function 8 10 Commissioning 9 11 Error Messages 11 12 Maintenance 11 13 Technical Information 12 14 Order Codes 12 15 Dimensions 13 16 EU Declarati...

Page 3: ...e in machines the measuring unit should be used only when the machines fulfil the EC machine guidelines 3 Instrument Inspection Instruments are checked before dispatch and should arrive in perfect con...

Page 4: ...bargraph by the individually blinking LED Sensor The model KAL D flow switch consists of a sensor with an evaluating electronic circuit The unit should only used for water like liquids for which the...

Page 5: ...flowing the heat generated in the sensor is transferred to the liquid i e the sensor is cooled The cooling time is an accurate measure of the flow speed The sensor signal is compared with the referen...

Page 6: ...lowing mounting position is recommended see figure below 7 Electrical Connection Caution Make sure that the electrical supply lines are de energized when connection the device Make sure the the supply...

Page 7: ...e switching point LED starts to blink more rapidly DUAL LED 2 The DUAL LED display indicates the following The switching point Red ALAM actual flow below setpoint Green FLOW actual flow above setpoint...

Page 8: ...nd GND GROUND 0 VDC NPN output type of contact N or M The NPN transistor output either grounds the output pin GROUND 0 VDC or is high resistance open circuit The maximum output current is 400 mA The l...

Page 9: ...complies with this directive First install the sensor complete the Mechanical connection then connect the electrical lines complete the Electrical connection After these steps are completed the zero...

Page 10: ...low The adjustment procedure is now complete It may be repeated as often as necessary c Measuring mode After adjustment the flow monitor is once again in measuring mode The flow is constantly monitore...

Page 11: ...r the settings are completed screw the cover tightly back on the housing make sure that the window for viewing the LED bargraph is aligned with the bargraph 11 Error Messages The sensor element itself...

Page 12: ...indicator on LED strip display blinking LED Output status indicator 1 dual LED Switching output Semiconductor PNP or NPN max 400 mA short circuit proof N O or N C contact set at the factory Electrical...

Page 13: ...KAL D KAL D K03 0516 page 13 15 Dimensions D C mm AF mm L M 12x1 23 19 40 5 G 1 4 26 19 40 5 G 1 2 43 27 55 5 1 4 NPT 26 19 40 5 1 2 NPT 43 27 55 5...

Page 14: ...onformity with the standards noted below EN 61000 6 4 2011 Electromagnetic compatibility EMC Part 6 4 Generic standards Emission standard for industrial environments EN 61000 6 2 2005 Electromagnetic...