HND-T105
HND-T105 K04/1016
page 7
7.4 Pushbuttons
key 1:
On/Off key
key 4:
Set/Menu
press (Menu) for 2 sec.: configuration
will activated
keys 2, 5:
min/max when taking measurements:
press shortly: min. or max. measuring
value will be displayed
press for 2 sec.: the min. or max. value
will be deleted
up/down for configuration:
to enter values or change settings
key 6:
Store/Quit
:
- Measurement: Hold current measuring
value ('HLD' in display)
- Menu: Acknowledge setting, return to
measuring
key 3:
no function
7.5 Device Configuration
For configuration of the device press "
Menu
"-key (key 4) for 2 seconds, the first
menu will be shown. Choose between the individual values that can be set by
pressing the "
Menu
"-key (key 4) again. The individual values are changed by
pressing the keys "
" (key 2) or "
" (key 5).
Use key "
Quit
" (key 6) to leave configuration and to store settings.
7.5.1
'Unit': Selection of Temperature Unit °C / °F
°C:
All temperature values are in degrees Celsius
°F:
All temperature values are in degrees Fahrenheit
7.5.2
'Resolution': The Display Resolution
0.1°:
Resolution 0.1 °C
0.01°:
Resolution 0.01 °C
Auto:
Resolution is selected automatically
7.5.3
'Offset': Zero Displacement
-2.50 °C...2.50 °C
respectively
-4.50 °F...4.50 °F
The zero point of the measurement will be displaced
by this value to compensate for deviations in the
temperature probe or in the measuring device
oFF
:
Zero displacement inactive (=0.0°)