DON
DON K36/1222
page 9
Incorrect installations will cause the
rotor weight to be felt on the bottom of
the measuring cavity.
6.2 Orientation
When installing the flowmeter, orientation must be considered. The rotor shafts
must be in a horizontal plane. To verify that the rotor shafts are in a horizontal
plane, electronic cover or optional digital display will be facing in a horizontal
direction. For modification in the field, the electronic cover or digital display can be
rotated in any 90 degree position. This accommodates access to the electrical entry
and allows the electronic display orientation to best suit the installation.
The DON flowmeter accommodates both horizontal and vertical flows. It is
recommended that for vertical flow installations that the liquid flow up through the
meter
(i.e. bottom to top
). This orientation assists in air or entrained gas removal.
The flow meter is bidirectional. To identify the flow direction, in which the flowmeter
was calibrated, the flowmeters are marked with arrows. These arrows are placed
on the lower side for models DON-x04 .. DON-x15 and on the top side for models
DON x20..DON-x60. The flowmeter calibration data refers to this arrow direction.
This is also the preferred flow direction.
C O R R E C T I N S T A L L A T I O N S
Note: orient the conduit entry downward
to avoid moisture migration into the
electronic cavity.
I N C O R R E C T
C O R R E C T I N S T A L L A T I O N S
Summary of Contents for DON -2/4
Page 1: ...Operating Instructions for Oval Gear Flow Meter Model DON...
Page 28: ...DON page 28 DON K36 1222 DON x25 to x40 DON x45 to x60...
Page 53: ...DON DON K36 1222 page 53 19 Statement of Conformity...
Page 54: ...DON page 54 DON K36 1222...
Page 55: ...DON DON K36 1222 page 55...
Page 56: ...DON page 56 DON K36 1222...
Page 57: ...DON DON K36 1222 page 57...
Page 58: ...DON page 58 DON K36 1222 20 Exd Certificate...
Page 59: ...DON DON K36 1222 page 59...
Page 60: ...DON page 60 DON K36 1222...
Page 61: ...DON DON K36 1222 page 61 21 IECEx Certificate...
Page 62: ...DON page 62 DON K36 1222...
Page 63: ...DON DON K36 1222 page 63...
Page 64: ...DON page 64 DON K36 1222...
Page 65: ...DON DON K36 1222 page 65 22 State of safeness...