DON K36/1222
6.3 Flow Conditioning and Location
It is highly recommended to INSTALL a filter immediately before (prior to) the
meter. Filters are available and sold separately.
Recommended Filter (e.g. MFR-DO...):
DON-x04…DON-x15: < 75 µm particle size (200 mesh)
DON-x20…DON-x35: < 150 µm particle size (100 mesh)
DON-x40…DON-x60: < 350 µm particle size (45 mesh)
Flow conditioning: Flow conditions is not required since the DON flowmeter does
not require any straight pipe runs before or after the flowmeter.
Location: The recommended installation would be before of any flow control and/or
shut off valves, this installation prevents complete emptying of the meter. This
minimizes the risk of leakage and/or air entrapment which could result in damage
to the flowmeter or inaccurate initial readings.
A by-pass installation is recommended for process or safety critical meters.
Isolation valves enable the meter to be isolated from the system and serviced as
needed. System purging is also possible with a by-pass arrangement.
Accommodate all meter ratings and locate the meter on the discharge side of the
process pump.
For outdoor applications, be sure all electrical entries are sealed properly via the
proper glands, mounting, sealing or containment. For humid environments, mount
the instrument appropriately as to avoid condensation build up. Generally, these
installations have the conduit connection pointing downward as to drain any
condensate away from the electronics.
Liquid State: Liquid within the flowmeter must not freeze. If heat tracing is
necessary, please be sure to adhere to the temperature limits of the flow meter.
Ensure the liquid does not flash, do not exceed the max DP of the flowmeter.
Hydraulic shock: Surge dampeners or pressure relief valves must be installed if
hydraulic shock or pressure spikes are present. Highly pulsating flow can also
damage the DON flowmeter. Diaphragm pumps and specific application profiles
can cause high frequency pulsating flow. Proper pulsating dampers are highly
recommended.
Summary of Contents for DON -2/4
Page 1: ...Operating Instructions for Oval Gear Flow Meter Model DON...
Page 28: ...DON page 28 DON K36 1222 DON x25 to x40 DON x45 to x60...
Page 53: ...DON DON K36 1222 page 53 19 Statement of Conformity...
Page 54: ...DON page 54 DON K36 1222...
Page 55: ...DON DON K36 1222 page 55...
Page 56: ...DON page 56 DON K36 1222...
Page 57: ...DON DON K36 1222 page 57...
Page 58: ...DON page 58 DON K36 1222 20 Exd Certificate...
Page 59: ...DON DON K36 1222 page 59...
Page 60: ...DON page 60 DON K36 1222...
Page 61: ...DON DON K36 1222 page 61 21 IECEx Certificate...
Page 62: ...DON page 62 DON K36 1222...
Page 63: ...DON DON K36 1222 page 63...
Page 64: ...DON page 64 DON K36 1222...
Page 65: ...DON DON K36 1222 page 65 22 State of safeness...