16. EU Declaration of Conformance 

We,  KOBOLD  Messring  GmbH,  Hofheim-Ts,  Germany,  declare  under  our  sole 
responsibility that the product: 
 

Digital Indicating Unit  

Model: DAG-A44 

 
to which this declaration relates is in conformity with the standards noted below:  

 

to which this declaration relates is in conformity with the standards noted below:  
 

EN 61010-1:2010+A1:2019+A1:2019/AC:2019

 

Safety  requirements  for  electrical  equipment  for  measurement,  control  and 
laboratory use  
 

EN 61326-1:2013

 

Electrical  equipment  for  measurement,  control  and  laboratory  use  -  EMC 
requirements - Part 1: General requirements 
 

EN 63000:2018

 

Technical documentation for the assessment of electrical and electronic products 
with respect to the restriction of hazardous substances 

 

 
Also, the following EC guidelines are fulfilled: 
 

2014/30/EU   

EMC Directive 

2014/35/EU

   

Low Voltage Directive 

2011/65/EU

   

RoHS

 (category 9) 

2015/863/EU

 

  Delegated Directive (RoHS III) 

 
 
 
 
 
Hofheim, 16 Jan. 2023 
 

H. Volz 

M. Wenzel 

 

General Manager 

Proxy Holder 

 

Summary of Contents for DAG-A44 Series

Page 1: ...Operating Instructions for Digital Indicating Unit PT100 2 3 wire 200 C 850 C 328 F 1562 F Model DAG A44 96 x 48 mm...

Page 2: ...s 2 2 Note 3 3 Instrument Inspection 4 4 Regulation Use 4 5 Assembly 5 6 Electrical connection 6 7 Function and operation description 7 8 Setting up the device 8 8 1 Switching on 8 8 2 Standard parame...

Page 3: ...uct version you can request it from us free of charge by email info de kobold com in PDF format specifying the relevant invoice number and serial number If you wish the operating instructions can also...

Page 4: ...damage please inform your parcel service forwarding agent immediately since they are responsible for damages during transit Scope of delivery The standard delivery includes Description instrument mode...

Page 5: ...oving the fixing elements insert the device 2 Check the seal to make sure it fits securely 3 Click the fixing elements back into place and tighten the clamping screws by hand Then use a screwdriver to...

Page 6: ...trinsic potential can be cancelled by a bridge from terminal 2 to 4 and thus stabilise the device against external failures Devices with a supply of 230 VAC need to connect terminal 3 to signal ground...

Page 7: ...tion Level The parameters stored in the menu item can be parameterized here Functions that can be adjusted or changed are always indicated with a flashing of the display Adjustments made at the parame...

Page 8: ...uence For 1 second during the switch on progress the segment test 8 8 8 8 is displayed followed by an indication of the software type and after that also for 1 second the software version After the st...

Page 9: ...DAG A44 DAG A44 K05 0123 page 9...

Page 10: ...K05 0123 8 3 Extended parameterization By pressing the buttons during standard parameterization for one second the display switches to the extended parameterization mode Operation is the same as in st...

Page 11: ...DAG A44 DAG A44 K05 0123 page 11...

Page 12: ...the Alarm S1 S2 is off below the threshold and on on reaching the Threshold Limit value undercut Low By limit value undercut the alarm S1 S2 is on below the threshold and switched off on reaching the...

Page 13: ...ing procedure should be used Switch off the power supply Press button P Switch on voltage supply and press P button until is shown in the display With reset the default values of the program table are...

Page 14: ...n Operating instructions data sheet approvals and further information via the QR code on the device or via www kobold com 12 Order Codes Operating instructions data sheet approvals and further informa...

Page 15: ...s relays solenoid valves etc near the device and supress any interference with the aid of RC spark extinguishing combinations or free wheeling diodes Keep input output and supply lines separate from o...

Page 16: ...DAG A44 page 16 DAG A44 K05 0123 14 Error elimination...

Page 17: ...ional disposal regulations and environmental regulations Batteries Batteries containing pollutants are marked with a sign consisting of a crossed out garbage can and the chemical symbol Cd Hg Li or Pb...

Page 18: ...9 Safety requirements for electrical equipment for measurement control and laboratory use EN 61326 1 2013 Electrical equipment for measurement control and laboratory use EMC requirements Part 1 Genera...