I.- OPERATING SYSTEM 

 
The vacuum cleaner can work from 105 to 135 V. 
 
The current must be of  3 to 4 Amps.  
 
There should be no abnormal noise or vibration, the carbon brushes spark should be small and uniform, and the commutator 
must have dark brown strip and uniform. 

 

 

II.-REPLACEMENT PROCEDURES 

 
1.- TO REPLACE MOTOR (10) 

1.1.- Pull release tab outward, at the same time pull cover up. 
1.2.- Remove the four screws (14). 
1.3.- Remove the cover (7). 
1.4.- Disconnect the line cord. 
1.5.- Remove the six screws (11) and remove the motor assembly (10). 
1.6.- Replace the motor (10) reconnect and reassemble. 
NOTE: Do not attempt to the repair motor send for service. 

 

2.- TO REPLACE THE ON-OFF SWITCH (2) 

2.1.- Follow steps 1.1 and 1.3. 
2.2.- Disconnect the two leads from the switch (2). 
Remove the three screws (8) the screw (9) and remove the cover top (4) replace the on-off switch reconnect and reassemble. 

 

3.- TO REPLACE THE LINE CORD 

3.1.- Follow steps 1.1 and 1.3. 
3.2.- Remove and replace the new line cord and reassemble as initially placed

 

4.- TO REPLACE THE FLOAT (15) 

4.1.- Follow steps 1.1 
4.2.- Remove the cage (16). 
4.3.- Remove and replace the float (15) 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 