USER MANUAL CENTRAL HEATING BOILER TYPE C38GC25; C38GC25-P; C38GC29; C38GC35; C38GC35-CH1; C38GC35-CH2
REV. 01.07.2019
15 din 37
4.2.2
Minimum necessary distances/ free spaces for mounting
Both for the mounting/ installation of the central
heating
BOILERs
and
for
later
maintenance
operations you will need the following minimum
distances (fig. 1.3), respectively minimum free spaces
for mounting:
– distance to the lateral: 100 mm
– distance to the bottom part: 250 mm
– distance to the upper part: 400 mm
- distance to the front part: 500 mm
Caution!
Danger of damaging the equipment by
incorrect setting!
The equipment can be mounted only on a flat, fixed
surface.
Note!
Minimum necessary distances/ free
spaces for mounting are valid also for mounting with/
within pieces of furniture.
4.2.3
Installing the boiler
- Drill two holes for fixing the center support (1);
- Mark the position of the exhaust / intake duct;
- Mount the support (1) with the supplied screws and screws (2, 3) on the wall (fig.1.4);
- Install the boiler (4) in position.
-for models:
C38GC25, C38GC29, C38GC35 si C38GC25-P
-for models
C38GC35-CH1
si
C38GC35-CH2
:
Fig. 1.3
Fig 1.4
Fig 1.4