Error signals  

Possible errors of the system are indicated by the following codes which appear on the display.  

Table 5: 

Meaning of error signals which appear on the display:

 

 

Codul 

Non-

volatila 

Semnificatie 

Mod resetare 

E01 

YES 

Problems of the feeding source 

AUTO- RESETTABLE when the cause 
diappears

 

E02 

NO 

Malfunction of the electronic board 

AUTO- RESETTABLE when the cause 
diappears

 

E04 

NO

 

Malfunctions of the interface mode 

AUTO- RESETTABLE when the cause 
diappears

 

E06 

NO

 

Frequent resetting of the electronic board 

Manually resettable by pressing RESET

 

E07 

NO

 

Installation parameters in the electronic board memory 
are corrupted 

Manually resettable by pressing RESET

 

E08 

YES 

Internal memory is corrupt 

Manually resettable by pressing RESET

 

E10 

NO 

Water system pressure is incorrect.  
Water pressure in the installation is too low (lower than 0,8 
bars).  
Resettable error when the cause disappears!  
Fill the installation with water to the recommended 
working pressure (1.5 bars) and monitor the pressure for a 
few days.If pressure continues to drop, check for water 
leakage on one of the joints of the thermal installation. If 
you checked and it is allright, but the presuure continues 
to drop, contact an authorised service company.   

AUTO- RESETTABLE when the cause 

diappears

 

E11 

YES 

Rapid increase of the output water temperature 

AUTO- RESETTABLE when the cause 
diappears

 

E13 

NO 

Difference between input/ output temperatures too big 

AUTO- RESETTABLE when the cause 
diappears

 

E15 

YES

 

No water flow signal when the boiler pump is activated 

Manually resettable by pressing RESET

 

E20 

YES

 

Failed burning after three attempts 

Manually resettable by pressing RESET

 

E22 

YES

 

Malfunction of flame detection  

Manually resettable by pressing RESET

 

E23 

YES

 

Malfunction of flame detection 

Manually resettable by pressing RESET

 

E25 

YES

 

BCU malfunction 

Manually resettable by pressing RESET

 

E30 

YES

 

Malfunctioning burnt gases sensor 

Manually resettable by pressing RESET

 

E31 

NO 

Malfunctioning thermal input sensor 

Manually resettable by pressing RESET 
when the cause disappears

 

E32 

NO 

Malfunctioning thermal output sensor 

Manually resettable by pressing RESET 
when the cause disappears

 

E35 

NO

 

Malfunctioning external temperature sensor   

Manually resettable by pressing RESET 
when the cause disappears

 

E36 

NO

 

Mafunctioning WHW temperature 

Manually resettable by pressing RESET 
when the cause disappears

 

E37 

NO

 

Malfunctioning boiler temperature sensor 1 

Manually resettable by pressing RESET 
when the cause disappears

 

E38 

NO

 

Malfunctioning boiler temperature sensor 2 

Manually resettable by pressing RESET 
when the cause disappears

 

E40 

YES 

Temperature of burning gases is too high 

Manually resettable by pressing RESET 
when the cause disappears

 

E41 

NO

 

Temperature of thermal agent on the thermal input is too 
high or too low 

Manually resettable by pressing RESET 
when the cause disappears

 

E42 

NO

 

Temperature of thermal agent on the thermal output is 
too high or too low 

Manually resettable by pressing RESET 
when the cause disappears

 

E45 

NO

 

External temperature too high 

Manually resettable by pressing RESET 
when the cause disappears

 

E46 

NO

 

WHW temperature too low/ too high 

Manually resettable by pressing RESET 
when the cause disappears

 

E47 

NO

 

Temperature displayed by boiler sensor 1 is too low/ high 

Manually resettable by pressing RESET 
when the cause disappears

 

E48 

NO

 

Temperature displayed by boiler sensor 2 is too low/ high 

Manually resettable by pressing RESET 
when the cause disappears

 

E50 

YES

 

Malfunctioning with feeding of ventilator at 230VAC 
Malfunctioning with fresh air intake / burned gases 
exhaust 
Malfunctioning with overheating thermostat 
Malfunctioning with differential air pressure-switch 

Manually resettable by pressing RESET

 

E51 

YES

 

Error with command/ state of ventilator 

Manually resettable by pressing RESET

 

E52 

YES

 

Incorrect ventilator functioning (ex. rotation) 

Manually resettable by pressing RESET

 

 

Summary of Contents for C22SPV23MEF

Page 1: ...t depending on the area and the purchase period KÖBER SRL no 25 Vaduri Al Tel 40 233 24 17 46 233 24 19 33 www motan ro KÖBER SRL VADURI BRANCH USER MANUAL GAS BOILER C32SPV24MEFB C32SPV31MEFB C22SPV23MEF Alexandru cel Bun Commune Neam 233 24 19 33 Fax 40 233 24 19 29 eamt 617511 Romania ...

Page 2: ...aphic context functioning state 11 9 2 7 Graphic context adjustment of functioning parameters 11 9 2 8 Graphic context Service submenu 12 9 3 Central heating station startup 12 9 4 Functioning as waste hot water station WHW 12 9 5 Functioning as heating station HS 12 9 6 Preset functions related to station safety 12 9 7 Setting additional functions 12 9 8 Error signals 13 9 9 Station switch off in...

Page 3: ...t not be used by people with limited psychological and sensitive capacities including children or by people with no experience or and no knowledge The station provides both heating in closed circuit central heating installations as well as hot water Use for other purposes or for additional purposes other than stipulated is considered inappropriate use The manufacturer is not responsible for possib...

Page 4: ...rmal circuit 0 5 3 5 bar Maximum pressure on DHW circuit 8 bar Temperature on thermal circuit 30 80 C Temperature on the floor heating system circuit 15 45 C Temperature on domestic hot water circuit 35 55 C Hot water flow t 30 C 10 l min Electric characteristics Input 230VAC 50 Hz Rated power EEI pump 0 2 80 W Construction characteristics Height 700 mm Width 436 mm Depth 306 mm 328 mm 306 mm Weig...

Page 5: ...ly in rooms with maximum 60 humidity between 20 30 C in order to prevent the damaging of electronic components Caution The burning air of the station must not contain substances such as flourine vapours chlorine sulphur dissolvants colorants adhesives or gasoline These substances can lead in time to the corrosion of the equipment and air gas incoming outgoing pipes Legend A Thermal input connector...

Page 6: ...allation of the central heating station in the proximity of a swimming pool washing machine or cleaner can result in the contamination of the burning air with these compounds Water pH must be within the following limits 7 5 pH 9 5 It is recommended to check the water and thermal agent pH frequently and if the value does not fall within the limits provided by the manufacturer it will be treated aga...

Page 7: ...filter on the return of the thermal circuit installation When installing connecting pipes it is essential for these not to be tensed to avoid creating areas of leakage Maximum working pressure allowed is 3bar Recommended working pressure is 1 5 bar Caution It is forbidden to use the central heating station without thermal agent or partilally filled danger of explosion It is forbidden to use the ce...

Page 8: ...ions must comply with applicable norms Connection to the electric grid of the building must allow the entire electric insulataion of the central heating station for situations when interventions are required Grid connection is done taking into account the symbolism of colours as follows Brown phase Blue null Green and Yellow earthing The current plug must be accessible so that the user can easily ...

Page 9: ...damage of the main switch of the station Incorrect airing of the installation can cause damage of the main heating switch Note Recommended pressure on the thermal circuit is 1 5 bars Emptying the central heating station Emptying of the station implies the following turn off the station by pressing Power si switch off the electric power close the gas tap close the thermal tap and the cold water inp...

Page 10: ...parameter in the installation submenu Used to decrease the set temperature on hot water circuit or the value parameter in the installation submenu Used to switch the station on off Used to reset the electronic control board from an error state Used to change the functioning mode winter summer Used to activate deactivate the light on the display Description of graphic symbols in the LCD display Des...

Page 11: ...tallation is 1 4 bar working mode is summer and the temperature in the installation is 17 C 9 2 6 Graphic context functioning state This state is associated with the presence of flame or the functioning of the circulation pump of the station In this state all the activating state elements of the central heating station are active and the burning request is accepted The display shows the delivered ...

Page 12: ...HW request has priority over the heating request in the winter mode The station can function as instant WHW or as accumulation boiler WHW the boiler is functioning of the station as an accumulation boiler WHW station please contact an authorised service company In intant regime the minimum flow of hot water detected by the station is 2 4 l min For confort in using the station as a WHW station we r...

Page 13: ...ESET E25 YES BCU malfunction Manually resettable by pressing RESET E30 YES Malfunctioning burnt gases sensor Manually resettable by pressing RESET E31 NO Malfunctioning thermal input sensor Manually resettable by pressing RESET when the cause disappears E32 NO Malfunctioning thermal output sensor Manually resettable by pressing RESET when the cause disappears E35 NO Malfunctioning external tempera...

Page 14: ...is signed table 2 by which the user signs that they are aware of the correct way of using the central heating station This statement is also signed by the authorized person who commissioned the central heating station The authorised person who commissions the station has the right to refuse to sign the station commissioning statement if they notice defects of the local connecting installations and...

Page 15: ...B C32SPV31MEFB C22SPV23MEF REV 12 06 2017 15 of 19 11 Drawings necessary for mounting and installation 11 1 Types of configurations for mounting for mural central heating stations with forced flue C32SPV24MEFB C32SPV31MEFB C12 C22 C32 C72 C82 C42 C52 C62 ...

Page 16: ...e 300mm B distance over the window ventilation hole 300mm C distance left right to the window ventilation hole 300mm D E distance from the roof gutter 250mm F distance from the garage roof balcony 250mm G distance to vertical gutter 250mm H distance to internal external corners 250mm H distance to windows doors 300mm I distance to ground balcony 300mm J distance over the door 600mm L distance to t...

Page 17: ...c curve Pump error codes If the pump has detecte one or more errors the bi colour LED 1 changes from green to red When an error is active LEDs indicate the type of error as presented in table 7 If more alarms are active at the same time LEDs show the rror with the highest priority Tab 7 Pump error codes 11 5 Hydraulic characteristic of non ER P pump Q PUMP FLOW mc h Display Meaning Pump action Rep...

Page 18: ...32SPV31MEFB C22SPV23MEF REV 12 06 2017 18 of 19 11 6 Functioning schemes covered by warranty 11 6 1 Central heating with radiators and instant preparation of domestic hot water 11 6 2 Underfloor central heating and instant preparation of domestic hot water ...

Page 19: ...SPV31MEFB C22SPV23MEF REV 12 06 2017 19 of 19 11 6 3 Central heating with radiators and accumulated preparation of domestic hot water accummulation boiler 11 6 4 Underfloor central heating and accumulated preparation of domestic hot water accummulation boiler ...

Reviews: