4.2.2

 

 

“SPAN” Trimpot:

 Adjust Range Size 

The span adjust trimpot adjusts the range of the meter. The range reported by the RFU will 
vary depending on mechanical linkages. This trimpot can be used to calibrate the hard-over 
angles. Referenc

Figure 1: Rudder Angle Indicator Overview

 

for the span trimpot location. 

4.3

 

F

UNCTIONAL 

T

EST

 

Before commencing normal operations with the installed unit(s). A functional test shall be 
conducted to ensure proper operation of the system as per the intended application and 
configuration. 

 

Functional testing should be done by qualified personnel only. The 
system functionality should be fully tested dockside before an open 
water sea trail is performed to ensure proper response of the 
system based on rudder commands. 

 

After installation perform the following function tests:  

1.

 

Center the rudder 
a.

 

Ensure that the meter displays 0°. If not, first adjust the RFU lever arm until it is 
centered at 0°.  If the RFU lever arm is already centered then the potentiometer 
inside the RFU will require adjustment. 

2.

 

Move the rudder to hard-over 
a.

 

Ensure that the meter displays the hard-

over angle. If not, adjust the ‘Span’ 

trimpot until it is at the correct angle. 

 

Summary of Contents for 7178 Series

Page 1: ...7178 Panoramic Rudder Angle Indicator Owner s Installation Operation Maintenance Manual...

Page 2: ...rev A MNL 7178 docx 2 of 19 NOTES RECORD DATA BEFORE INSTALLATION FOR FUTURE REFERENCE Model Serial Date of Purchase Date of Installation...

Page 3: ...ation 8 3 1 Mechanical 8 3 2 Electrical 8 4 Commissioning 10 4 1 Electrical Check 10 4 2 Calibration and Adjustment 10 4 3 Functional Test 11 5 Maintenance 12 5 1 Preventative maintenance 12 5 2 Recom...

Page 4: ...sted by the user to ensure proper function in all possible applications For further instructions please contact our distributors or visit our website 1 2 SAFETY 1 2 1 Safety Alerts Throughout this man...

Page 5: ...qualified personnel are persons who are familiar with the assembly installation commissioning and operation of the product and who have the qualifications necessary for their occupation Observe all sp...

Page 6: ...r displays rudder angle position on three scales to provide 230 degrees of viewing angle within the Vessel s bridge The indicator is driven by a position transducer such as the Kobelt 7163 7168 or 717...

Page 7: ...IEC 60945 COMPASS SAFE DISTANCE 2 in 5 cm ENVIRONMENTAL CATEGORY ENV2 class A protected INGRESS PROTECTION IP20 OPERATING TEMPERATURE 4 F 131 F 20 C 55 C ENVIRONMENTAL CONDITIONS per DNV No 2 4 VIBRAT...

Page 8: ...ors for external connections to the power supply and rudder feedback unit The RFU cable must be twisted pair and shielded to protect the signal integrity Use ferrules on the cable ends for all wire co...

Page 9: ...rev A MNL 7178 docx 9 of 19 Figure 2 Electrical Connections Disconnect Power Turn off power at distribution panel before beginning installation to protect installer from electrical hazards...

Page 10: ...wdriver or other equivalent tool to adjust the trimpot Exercise caution when reaching in with the screwdriver Do not let it touch any components other than the trimpot Ensure no oil or other contamina...

Page 11: ...r the intended application and configuration Functional testing should be done by qualified personnel only The system functionality should be fully tested dockside before an open water sea trail is pe...

Page 12: ...QTY ITEM KOBELT PART 4 T3 1 4 BULB 24 VDC ANSI Model 464 6001 3641 4 T3 1 4 BULB 12 VDC ANSI Model 193 6001 3642 Select the spare bulb based on the desired operating voltage Bulbs are the same for al...

Page 13: ...the chip locate it on the board using Figure 3 Motor driver Chip below gently pry out the old chip and press in the replacement Figure 3 Motor driver Chip It is recommended that any required service...

Page 14: ...k the lightbulb installation and ensure that all connections have been properly made Dimming is turned down all the way Adjust the dimming knob until the 7178 unit is adequately illuminated 7178 illum...

Page 15: ...issue or defect with a Kobelt Product or Part the Warranty Applicant Applicant must immediately contact Kobelt and describe the issue in writing by letter fax email or other electronic conveyance Kob...

Page 16: ...rev A MNL 7178 docx 16 of 19 8 APPENDIX A INSTALLATION DIMENSIONS Figure 4 Mechanical Dimensions of 7178...

Page 17: ...rev A MNL 7178 docx 17 of 19 9 APPENDIX B PARTS LIST...

Page 18: ...X 1 4 18 8 1 22 1 1024 0512 SPRING PIN 1 8 X 3 4 AISI 420 1 23 1 1024 0516 SPRING PIN 1 8 X 1 AISI 420 1 24 2 1012 0606 SCREW PAN HD PHL DRIVE 6 32 x 3 8IN 18 8 SS 1 25 2 1023 0106 WASHER FLAT 6 ANSI...

Page 19: ...lt Manufacturing Co Ltd 8238 129th Street Surrey British Columbia Canada V3W 0A6 Sales Tel 1 604 572 3935 Fax 1 604 590 8313 Email sales kobelt com Website www kobelt com Made in Canada Printed in Can...

Reviews: