background image

 

10 

 

Wiring to Power Supply 

 

 THIS  RANGE  HOOD  MUST  BE  PROPERLY 

GROUNDED.    MAKE  SURE  THIS  IS  DONE  BY 
QUALIFIED  ELECTRICIAN  IN  ACCORDANCE 
WITH ALL APPLICABLE NATIONAL AND LOCAL 
ELECTRICAL  CODES.    BEFORE  CONNECTING 
WIRES,  SWITCH  POWER  OFF  AT  SERVICE 
PANEL  AND  LOCK  SERVICE  PANEL  TO 
PREVENT
 POWER FROM BEING SWITCHED ON 
ACCIDENTALLY. 

If  hood  is  operating  normally,  connect  three 
wires (black, white and green) to house wires 
and cap with wire connectors. 

Store wires in the wiring box. 

 

Ductwork Installation 

 

4.  Use  steel  pipe  to  connect  the  exhaust  on  the 

hood to the ductwork.  Use duct tape to make all 
joints secure and air tight.   
 

Duct Cover Installation 

 

5.  Mark  the  position  of  the  Duct  Cover-Mounting 

Bracket {F}.  Use reference E from Table 2 and 
measurements  on  page  14-15.    Attach  and 
secure  Duct  Cover-Mounting  Bracket  {F}  with 
two  screws  (provided).    Refer  to  Figure  12.  
NOTE:  Inner  duct  cover  will  cover  the  Duct 
Cover-Mounting Bracket. 

6.  Remove  the  Baffle  Filters.    Position  the  entire 

duct cover up onto the hood and secure with six 
(3/16”  x  3/8”)  screws  {H}  from  inside  the  hood 
towards the outer duct cover.  

7.  Secure  the  inner  duct  cover  with  two  (3/16”  x 

3/8”)  screws  {H}  to  the  Duct  Cover-Mounting 
Bracket {F}. Shown in Figure 13. 

 

Install / Uninstall Accessories 

 

8.  Place baffle filters underneath the hood. (Figure 

14) 

 

Final Assembly 

 

9.  Turn power ON in control panel.  Check all lights 

and fan operation. 

10. Leave  this  Installation Instructions  and  Operation 

Manual for the homeowner. 

 
 
 
 

Figure 12 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Figure 13 
 
 
 
 
 
 
 
 
 
 
 
 

 

Figure 14 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Attach Together 

Summary of Contents for RA3830SQB-5

Page 1: ...KOBE Range Hoods Deluxe Series RA38 SQB 5 Series Model No Under Cabinet RA3830SQB 5 30 RA3836SQB 5 36 Wall Mount RA3830SQB WM 5 30 RA3836SQB WM 5 36 INSTALLATION INSTRUCTIONS AND OPERATION MANUAL...

Page 2: ...T INSTALL THE UNIT AND KEEP ALL ORIGINAL PACKAGING MATERIAL 2 Have your original invoice as proof of purchase and product serial number ready 3 Contact your merchant for product replacement due to shi...

Page 3: ...E 12 SPECIFICATIONS 13 MEASUREMENTS DIAGRAMS 14 PARTS LIST 16 CIRCUIT DIAGRAM 18 TROUBLE SHOOTING 19 WARRANTY 20 WARRANTY INFORMATION FORM 22 READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING A L L W I...

Page 4: ...atment negligence or any other circumstances beyond the control of KOBE RANGE HOODS authorized agents Any repair carried out without the supervision of KOBE RANGE HOODS authorized agents will automati...

Page 5: ...ou still smell gas call the Gas Company and Fire Department right away CAUTION 1 For general ventilation use only Do not use to exhaust hazardous or explosive materials and vapors 2 To reduce the risk...

Page 6: ...e Hood B Warranty Registration Card C Quick Reference Guide D Baffle Filter x 2 30 hood x 3 36 hood E 6 Round Plastic Collar F Wire Cap x 3 G Screws Package A B C D Knob is attached to baffle filter E...

Page 7: ...ide D Baffle Filter x 2 30 hood x 3 36 hood E 6 Round Plastic Collar F Duct cover Mounting Bracket G Adjustable Duct Cover H Screws Package I Wire Cap x 3 J Screws Package A B C D Knob is attached to...

Page 8: ...ing B Height of Floor to Counter Top Standard 36 C Preferred Height of Counter Top to Hood Bottom Minimum 26 to 30 D Height of Hood E Height of the Cabinet FOR WALL MOUNT WITH OPTIONAL DUCT COVER TABL...

Page 9: ...SHARP EDGES PLEASE WEAR PROTECTIVE GLOVES IF REMOVING ANY PARTS FOR INSTALLING CLEANING OR SERVICING NOTE BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER DAMAGE TO THE HOOD MAY OCCUR Installation Conten...

Page 10: ...e and create access opening for electrical wires and exhaust under the cabinet Hood Installation CAUTION USE HAND TOOLS ONLY DO NOT OVER TIGHTEN SCREWS IT MAY CAUSE DAMAGE TO THE HOOD CAUTION If movin...

Page 11: ...CAL CODES BEFORE CONNECTING WIRES SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY If hood is operating normally connect three wires black...

Page 12: ...allation Using references on Table 2 and measurements on page 14 15 decide the level of the lumber Refer to Figure 9 Hood Installation CAUTION USE HAND TOOLS ONLY DO NOT OVER TIGHTEN SCREWS IT MAY CAU...

Page 13: ...the position of the Duct Cover Mounting Bracket F Use reference E from Table 2 and measurements on page 14 15 Attach and secure Duct Cover Mounting Bracket F with two screws provided Refer to Figure...

Page 14: ...r cooking and keep fans running while cooking Adjust speed as needed To operate the fan function Press button to choose from speed o Q QuietMode speed o L Low speed o H High speed Press OFF to turn fa...

Page 15: ...orn spots Use dry soft towel to dry the hood 3 DO NOT allow deposits to accumulate or remain on the hood 4 DO NOT use ordinary steel wool or steel brushes Small bits of steel may adhere to the surface...

Page 16: ...9 3 4 x 20 1 2 x 12 5 8 RA3836SQB 5 and RA3836SQB WM 5 35 3 4 x 20 1 2 x 12 5 8 OPTIONAL ACCESSORIES W x D x H 1 30 Stainless Steel Back Panel SSP30 30 x 1 10 x 32 2 36 Stainless Steel Back Panel SSP3...

Page 17: ...measurements are converted from millimeters Inch measurements are estimated All measurements in are millimeters FOR UNDER THE CABINET MODEL NO RA3830SQB 5 30 RA3836SQB 5 36 FOR WALL MOUNT MODEL NO RA...

Page 18: ...15 Hood Mounting Bracket Duct Cover Mounting Bracket...

Page 19: ...0401 0120 04 Capacitor x 1 RA3836SQB 5 L1 0401 0120 24 3 LED Light Driver L1 0402 D001 4 Capacitor Box L1 0524 0003 5 LED Light 3W x 2 L1 0403 0301 6 Control Panel Bracket L1 0207 3830 7 Control Switc...

Page 20: ...apacitor x 1 RA3830SQB WM 5 L1 0401 0120 04 Capacitor x 1 RA3836SQB WM 5 L1 0401 0120 24 5 LED Light Driver L1 0402 D001 6 Capacitor Box L1 0524 0003 7 LED Light 3W x 2 L1 0403 0301 8 Control Panel Br...

Page 21: ...18 CIRCUIT DIAGRAM MODEL NO RA3830SQB 5 30 RA3836SQB 5 36 RA3830SQB WM 5 30 RA3836SQB WM 5 36...

Page 22: ...tive Replace LED light fixture s The light wiring s is loose Check wire continuity from Control Panel to LED Driver to LED light fixture s The control panel or LED light driver is defective Replace th...

Page 23: ...ed States and Canada It is non transferable and applies only to the original purchaser and does not extend to subsequent owner of this product In Hawaii Alaska and Canada this warranty is limited Ther...

Page 24: ...ervice you will be responsible for all expenses associated with the requested service including parts labor shipping travelling and any other expense related to the service request TO REQUEST WARRANTY...

Page 25: ...1 Date of purchase 2 Model No 3 Serial No For warranty service or spare parts purchase contact KOBE Service Center USA ONLY Toll Free 1 877 BUY KOBE 289 5623 Email customer service koberangehoods com...

Page 26: ...s recommand d utiliser cette hotte l tranger puisque l alimentation lectrique pourrait ne pas tre compatible et enfreindre le code de l lectricit de ce pays L usage de la hotte KOBE l tranger est votr...

Reviews: