background image

2

7

KOBE

PROFESSIONAL

AIR TOOLS

SAFETY INSTRUCTIONS

You have purchased a quality professional product that is designed for high

performance and long service life. If correct use, safety and maintenance

procedures are observed this machine will last for many years.

KOBE  PROFESSIONAL AIR  TOOLS

have  been  specifically  designed  to  help  you  work

SAFELY

and 

EFFICIENTLY

.  Your  care  and  good  judgement  are  the  best  protection  against  injury,  but

always ensure that the appropriate safety equipment is worn. All possible hazards cannot be covered here,

but the most important ones have been highlighted.

l

Always  adhere  to  the  processes  and  safety

warnings,  which  are  stated  in  the  instruction

manual  of  your  air  tools  which  are  used  in

conjunction with your air compressor.

GENERAL OPERATING HAZARDS

l

Always  ensure  the  mains  power  supply

corresponds to the power rating on the data label

on the machine.

l

Always  plug  the  air  compressor  into  an

appropriate  outlet  that  is  properly  installed  and

grounded.  Check  with  a  qualified  electrician  if

you  are  in  doubt  as  to  whether  the  outlet  is

properly grounded.

l

Always  disconnect  from  the  electrical  power

supply  and  ensure  that  all  the  compressed  air

has been released from the receiver tank before

cleaning or carrying out user maintenance.

l

Always stay alert and watch what you are doing.

l

Always  ensure  the  maintenance  of  electrical

components is carried out by a suitably qualified

person.

l

Never operate the air compressor or any air tool

when  tired  or  under  the  influence  of  alcohol  or

prescription/non-prescription drugs.

l

Never  operate  if  any  parts  are  missing  or

damaged.

l

Never touch the metal plug pins when connecting

or removing the electrical plug.

WORKPLACE HAZARDS

l

Always keep the high pressure hose and electric

cable away from heat and sharp edges.

l

Always  use  a  RCD  (Residual  Current  Device)  to

provide protection against electric shock.

l

Never use plastic pipe for high pressure air line

as it could shatter,resulting in serious injury.

l

Never  leave  inflammable  objects  near  the

compressor.

l

Never  run  the  air  compressor  in  areas  exposed

to water or in damp conditions. 

l

Never  direct    jets  of  water  or  flammable  liquids

over the air compressor.

l

Never  use  the  air  compressor  near  naked

flames.

PERSONAL PROTECTION

l

Always  wear  approved  eye  protection  during

operation. 

l

Always ensure that all long hair and loose clothing,

ties, scarves, jewellery, etc., are secured or

removed. 

l

Never  direct  air  at  yourself,  anyone  else  or  at

animals.

SPECIFIC OPERATING HAZARDS

l

Always use recommended attachments or parts.

l

Always use the handle to move the compressor.

Do not move it by any other means.

l

Always  place  the  air  compressor  on  a  firm  and

level surface.

l

Always ensure the electric cable is not damaged

before  connecting  the  air  compressor  to  the

electricity supply.

l

Always switch off using the on/off lever when the

air compressor is not in use. This will avoid any

unintentional starting.

l

Always  close  the  tap  and  discharge  residual

pressure in the air hose before disconnecting the

air hose from the compressor.

l

Always  check  for  damaged  or  loose  hoses  and

fittings.  Whipping  hoses  can  cause  serious

injury.

l

Always be careful when handling the compressor

as components such as the delivery pipe and the

cooling fins of the cylinder head can become very

hot and remain hot for some time after use. 

l

Never  tamper  with,  or  attempt  to  adjust  the

pressure  switch  or  the  safety  valve.  The  air

compressor  must  always  be  serviced  by  an

authorised agent.

l

Never  use  the  air  compressor  without  the  air

filter attached.

l

Never use the air compressor for filling breathing

tanks, diving tanks or for pharmaceutical, food or

health applications.

SYMBOLS USED ON THE AIR COMPRESSOR

Warning

Hot components        Shock hazard         WEEE Symbol              Read the operator’s manual

KOBE

PROFESSIONAL

AIR TOOLS

TROUBLESHOOTING 

Continued

KOBE

PROFESSIONAL

AIR TOOLS

SERVICE & REPAIR

A comprehensive repair and service

facility  is  available  through  your

local agent.

KOBE

PROFESSIONAL

AIR TOOLS

SPARES

For spare parts or servicing please contact your nearest agent. Remember to quote tool model number and

spare  part  number  when  ordering  spares.  The  use  of  other  than  genuine  Kobe  replacement  parts  may

result  in  safety  hazards,  decreased  tool  performance  and  increased  maintenance.  When  disposing  of

components, etc. ensure that relevant environmental procedures are carried out.

Air Intake Filter unit

KBE-298-4846Y

Filter Eelement

KBE-298-4847Z

Drain valve

KBE-298-4866T

Check Valve set

KBE-298-4873A

Fig. 10

Valve seat

POSSIBLE CAUSE

The pre-set pressure

switch is defective or

needs adjusting.

Faulty safety blow off

valve.

SOLUTION

Stop the air compressor immediately and

contact your local Kobe agent.

Contact your local Kobe agent.

FAULT

The motor pump unit does

not stop when the tank

pressure reaches its

maximum working

pressure (116PSI) and the

safety valve vents air.

Safety blow off valve

operates below the

maximum pressure.

Reviews: