51
Data Name
Type
Address
Attribute
Command
[HEX]
Description
Historical Record No.
Long
40019
W
10
For Record Query.
Historical Record Data
Packet
12-Short
40021
~40032
R
03
Char 1~8:
1: Second.
2: Minute.
3: Hour.
4: Day.
5: Month.
6: Week.
7: Year.
8: 14H [20D]
Char 9~12: Totalized Loading
Weight [Long]
Char 13~14: Bucket Count [Short]
Char 15~24: Goods [ASCII]
Note: ‘Char1=2DH’ means ‘No
Record’.
Record Query: Write the ‘Record No.’ for query into the register [40019] at first, then read the whole data packet of the