www.grupotemper.com 13
KMD-11
AUTORANGING MULTIMETER
measurements. For measurement situations requiring that a range be
manually selected, perform the following:
1. Press the
RANGE
key. The “
AUTO”
display indicator will turn off
or select diode /beeper, AC/DC Clamp
2. Press the
RANGE
key to step through the available ranges until you
select the range you want.
3. To exit the Manual Ranging mode and return to Autoranging, press
and hold the
RANGE
key for 2 seconds.
Note:
Manual ranging does not apply for the Frequency functions.
MAX/MIN
Note:
When using the MAX/MIN function in Autoranging mode, the
meter will “lock” into the range that is displayed on the LCD
when MAX/MIN is activated. If a MAX/Min reading exceeds
that range, an “
OL
” will be displayed. Select the desired range
BEFORE entering MAX/MIN mode.
1.
Press the
MAX/MIN
key to activate the MAX/MIN recording mode.
The display icon "
MAX
" will appear. The meter will display and hold
the maximum reading and will update only when a new “max”
occurs.
2.
Press the
MAX/MIN
key again and the display icon "
MIN
" will
appear. The meter will display and hold the minimum reading and