KDC200 Programming Manual
short intervals.
‘bT70’
command
Parameters: None
Format:
‘bT70’
Output:
‘
value
@’ where
value
is the timeout value of bluetooth module auto power off
Purpose:
Getting current bluetooth auto power off timeout value
‘bT71’
command
Parameters:
value
Format:
‘bT71
value#
’ where
value
is the timeout value of bluetooth module auto power off
Output:
‘@’ all the time.
Purpose:
Setting current bluetooth auto power off timeout value from 1 minute to 30 minutes. It will be set
to 5 minute if
value
is 0 and 30 if
value
is greater than 30.
‘C’
command
Parameters: Date and Time value to be set in KDC200
Format: ‘C
YMDHmS
’ where Y is year(0 means 2000), M is month(1-12), D is day(1-31), H is hour(0-23),
m is minute(0-59) an S is second(0-59).
Output:
‘@’ all the times
Purpose:
Set Date and Time of KDC200.
‘c’
command
Parameters: None
Format: ‘c’
Output: ‘
YMDHmS
@’ where Y is year(0 means 2000), M is month(1-12), D is day(1-31), H is hour(0-23),
m is minute(0-59) an S is second(0-59).
Purpose:
Read current Date and Time of KDC200.