KNX Multiroom amplifier
6
LED feedback
The front panel of the Multiroom amplifier has LEDs, which are grouped as follows:
Channel LEDs:
8 x LED
Input
8 x LED
Output
Status LEDs:
1 x Power
1 x Data
1 x Warning (Symbol "
!
")
1 x Mute (Symbol "Struck-through loudspeaker")
Function
POWER
LED
Warning
LED
Data
LED
Mute
LED
OUTPUT
LEDs
Boot sequence completed
On
x
x
x
x
Overheat alarm
x
On
x
x
x
KNX data traffic
x
x
Flashing
x
x
Saving data
Flashing
x
x
x
x
Master Mute On
x
x
x
On
x
Master Mute Off
x
x
x
Off
x
Start-up
Loading the address and application software
•
Switch on the mains voltage.
•
Switch on the bus voltage.
•
Assign the physical address and note it down on the device label.
•
Start up the device with start-up software.
•
Load the application software into the device.
i Programming is also possible without the mains voltage.