background image

3.3

Connector Panel Overview

The image below shows the connector panel located on the rear of the Chirp 3200 Series Echosounder. This image
is for a Chirp 3202 Dual Channel system with the possible expansion ports to upgrade to a Chirp 3204 Quad
Channel system.

3.3.1

Input Power

The Chirp 3200 needs to be powered from a AC source. The input voltage range is 90-264 VAC (nominal
120VAC). The power consumption of the Chirp 3202 is 60W and the Chirp 3204 is 100W.

3.3.2

Analog  Output

These are standard BNC connections which provide direct access to the analog signal after bandpass anti-aliasing
filters. This interface is useful for oscilloscope viewing of the output signal. The expected signal levels are between
0-5 volts.

3.3.3

Sync In / Out

The Sync In allows the output transmit of the Chirp 3200 to be synced to another piece of equipment. The SYNC
IN looks for a high-to-low-to-high transition with a low cycle hold time of at least 1ms but less than 50ms (min
ping rate). The transmit will occur on the rising edge on the sync signal. The SYNC OUT will provide a signal
from Channel 1.

3.3.4

Transmit (TX) Output

The TX Output connection transfers the high voltage transmit output signal to the transducer as well as the return
echo to the echosounder. CAUTION: Make sure that the Chirp 3200 is not transmitting while connecting or
disconnecting the transducer to the Tx Output connection.

3.3.5

USB Interface

D101-05530

6 of 11

Summary of Contents for Chirp 3200 Series

Page 1: ...0 SERIES USER MANUAL D101 05530 Revision 1 Knudsen Engineering Limited 10 Industrial Road Perth Ontario Canada K7H 3P2 Phone 613 267 1165 Fax 613 267 7085 www knudsenengineering com info knudsenengine...

Page 2: ...utput 6 3 3 3 Sync In Out 6 3 3 4 Transmit TX Output 6 3 3 5 USB Interface 6 3 4 System Connection 7 3 4 1 Peripherals 7 3 4 2 Data Logging 7 3 5 Transducer Installation 7 3 5 1 Over the Side 7 3 5 2...

Page 3: ...local representative or Technical Support Knudsen Engineering Limited 10 Industrial Road Perth Ontario K7H 3P2 Voice 613 267 1165 8 30 am to 5 00 pm E S T Core Hours Fax 613 267 7085 E Mail support kn...

Page 4: ...channels capable of up to 2kW of output power and two capable of up to 1kW of output power 2 2 Physical Characteristics The Chirp 3200 Series Echosounder is housed in a standard 3U rack case A summary...

Page 5: ...hirp 3200 is a black box echosounder that utilizes a PC to allow the user to control all system parameters manage peripherals record entire echogram data as well as internal and external data logging...

Page 6: ...face is useful for oscilloscope viewing of the output signal The expected signal levels are between 0 5 volts 3 3 3 Sync In Out The Sync In allows the output transmit of the Chirp 3200 to be synced to...

Page 7: ...o the end of a pole that is fastened to the side of the boat The majority of the transducers that are sold by Knudsen Engineering Limited have the option to be purchased with a mounting adapter The ad...

Page 8: ...the transducer transmits and receives either through the hull itself or through an acoustic window The sea chest will need to be filled with water and may need a stand pipe to provide proper pressure...

Page 9: ...approximately 25 of the configured total output power The Gain can be selected manually or automatically recommended Shorter pulse lengths are to be used in shallow waters and longer pulse lengths in...

Page 10: ...confirm operation It may be that the LED has failed If problem continues contact Knudsen Engineering Limited 5 2 No Output to Transducer Confirm that the proper transducer has been connected to the e...

Page 11: ...Line Pin N Neutral Pin G Ground Transmit Output Pin A Out Pin B Shield Pin C Out Mating Cable End Manufacturer AMPHENOL Part Number MS3476W12 3P USB Pin 1 Power Pin 2 Data Pin 3 Data Pin 4 Shield L N...