26
RS232 COMMAND FORMAT
All commands consist of 3 alpha characters followed by a request, all enclosed in parentheses.
The request can be a read request (indicated by a “?”) or a write request (indicated by 1 to 4
ASCII digits).
A read request format (AAA?) where
(
starts the command
AAA
denotes the command
?
denotes the read request
)
ends the command
A read command returns the range and the current setting, for example:
Function
Command
Response
Brightness
(BRT?)
(0-22,10)
Lamp hours
(LMP?)
0-9999,421)
A write request example: (AAA####) where
(
starts the command
AAA
denotes the command
####
denotes the value to be written (leading in zeros not necessary)
)
ends the command
Some commands have ranges, while others are absolute. If a number greater than the maximum
range is received, it is automatically set to the maximum number for that function. If a command
is received that is not understood, a “?” is returned. With absolute settings, “0” is off, 1-999 is on.
The one exception is the Power command, where 0 is off and 1 is on.
Function
Command
Response
Brightness
(BRT10)
Sets brightness to 10
Power
(PWR0)
Turns power off
Power
(PWR1)
Turns power on
Power
(PWR9999)
?
Summary of Contents for HDP404