68
—
Command Group 03
ASCII
HEX
Function
Description
Return
Value
1:Normal
2:Dynamic Eco
VXXS0319n 56h Xh Xh 53h 30h 33h 31h 39h nh 0Dh Set Lamp Mode
0:Eco
1:Normal
2:Dynamic Eco
P/F
VXXG0321 56h xh xh 47h 30h 33h 32h 31h 0Dh
Get Splash Logo
0:On
1:Off
Pn/F
VXXS0321n 56h xh xh 53h 30h 33h 32h 31h nh 0Dh Set Splash Logo
0:On
1:Off
P/F
VXXG0322 56h xh xh 47h 30h 33h 32h 32h 0Dh
Get Fan Speed
0:Normal
1:High
Pn/F
VXXS0322n 56h xh xh 53h 30h 33h 32h 32h nh 0Dh Set Fan Speed
0:Normal
1:High
P/F
VXXG0358 56h xh xh 47h 30h 33h 35h 38h 0Dh
Get IR On/Off
Control
0:Both IR turn on
1:Front IR turn on
2:Back IR turn on
3:Both IR turn off
Pn/F
VXXS0358n 56h xh xh 53h 30h 33h 35h 38h nh 0Dh Set IR On/Off
Control
0:Both IR turn on
1:Front IR turn on
2:Back IR turn on
3:Both IR turn off
P/F