Installation Tips 

 
1. Follow all local electrical & building code requirements. 

 
2. The DIR54 is usually mounted in the wall behind the source 

equipment (receiver, CD player etc.). The system requires up to 
12 Knoll digital infrared receivers (can be mixed or matched), 
up to four single or dual emitters, an unregulated 12 VDC power 

supply and this DIR54 connection block. 
 

3. The two conductor emitter wires can be extended up to 
1000’. Wires can be solid or stranded, shielded or unshielded 

with a minimum of 28 gauge for runs under 200’, 22 gauge for 
runs under 500’ and 20 gauge for runs up to 1000’. 

 
4. The three conductor wires to the receivers can be extended 
up to 1000’. Wires can be solid or stranded, shielded or 

unshielded with a minimum of 28 gauge for runs under 200’, 22 
gauge for runs under 500’ and 20 gauge for runs up to 1000’. 

 
5. Plug in the single or dual emitter(s) into any of the four 3.5 

mm jack ports. If you are going to extend the emitter wire, 
carefully observe polarity. 

 

6. Connect the up to twelve Knoll digital infrared receivers into 
the detachable three-position connector with the wires in 

parallel. Again polarity is very important. 
 

7. Plug in the PS1202 or other unregulated 12 VDC power 
supply and the digital infrared system should be ready to go.   

 
8. The infrared system is usually left plugged in all the time (to 
an unswitched outlet) as it uses very little power. 

 
9. Test the digital infrared system to see if it is working 

properly. If it works only from a very close range or it does not 
work at all, first mark where the pot adjustment is on the DIR54 

blue color pot on the rear of the DIR54. This is so you can reset 
it to that starting point again. Try adjusting the pot on the 

connection block very slightly left and right as you are testing 
the receiver with the remote control. This may require two 
people. Adjust it until the maximum distance from the remote 

control to the Knoll digital infrared receiver is achieved. This 
should correct for the problem. If it still does not work properly, 

please call Knoll Systems and ask for infrared technical support 
at 1-800-566-5579. The help line is open from 7:30 a.m. to 

5:00 p.m. Monday to Friday Pacific time. 
  

DIR54

Emitter

  Ports

 Connect to

IR Receivers

12 VDC

Adjust

   pot

12V

GND

SIG