If you chose DOOR as machine type, you will see
the following menu...
•
If you chose CONVEYOR as machine type, you will
see the following menu...
Use SCROLL to choose liquid or dry as the type of detergent, then press
ENTER to continue.
There is also a “SMALL TANK” setting that can be selected for special
applications to enhance dry detergent feed in probe mode (does not apply to
probeless). If SMALL TANK is selected, the detergent feed rate will be more
aggressive when the concentration reading is within 5 Knight units of the
setpoint. Additionally, the detergent alarm (delay) function will be by-passed
when the concentration reading is within 3 Knight units of the setpoint.
DETERGENT TYPE:
LIQUID_
You will be prompted if you wish to reset the system. This function is
recommended for new installations and allows you to clear all memory and
set the unit back to default parameters.
Hold down on the SCROLL and DOWN buttons until you see the message
“RESETTING EVERYTHING“ then release both buttons. After a few
seconds, the memory will be cleared and the display will return to the display
at left. Press ENTER to continue.
SCROLL & DOWN TO
RESET EVERYTHING
Use SCROLL to choose whether you wish to have the sanitizer pump run
(simultaneously) with the rinse pump, or the detergent pump, then press
ENTER to continue.
SANI RUNS WITH:
RINSE_PUMP
This feature will stop the rinse pump after XX
seconds of continuous rinse signal, conserving
rinse agent on door-type dishmachines that fill
through the rinse valve.
Use
/
to choose from 0 to 60 seconds, then
press ENTER to continue.
RINSE LIMIT:
60 SEC
You will be prompted for the rack time. Use a
stop-watch (if available) to clock the time it takes
for one rack to pass through the rinse arm on the
machine. Use
/
to choose from 10 to 255
seconds, then press ENTER to continue.
RACK TIME:
10 SEC
This feature delays the operation of the rinse
pump for a selectable time once the rinse signal
is received. The delay time helps to conserve
rinse agent on door-type dishwashers (using with
conveyor machines is not typical for this feature).
Use
/
to choose from 0 to 60 seconds, then
press ENTER to continue.
RINSE DELAY:
00 SEC
You will only see this display if using probeless
detergent mode. This setting locks out the initial
charge for the time specified (from the previous
initial charge). This prevents over-use of chemical
if the detergent signal energizes unexpectedly
during operation. Use
/
to choose from 0 to
120 minutes, then press ENTER to continue.
INIT CHRG LOKOUT
01 MINUTES
Summary of Contents for UniTech Warewash
Page 1: ...0900591 Rev A 07 04 Page 1 of 24 UniTech Warewash Instruction Manual ...
Page 16: ...Page 16 of 24 0900591 Rev A 07 04 PARTS DIAGRAM ALL CONFIGURATIONS ...
Page 17: ...0900591 Rev A 07 04 Page 17 of 24 PARTS DIAGRAM LIQUID DETERGENT ...
Page 18: ...Page 18 of 24 0900591 Rev A 07 04 PARTS DIAGRAM DRY DETERGENT Brass Solenoid Model ...
Page 19: ...0900591 Rev A 07 04 Page 19 of 24 PARTS DIAGRAM DRY DETERGENT Plastic Solenoid Model ...
Page 20: ...Page 20 of 24 0900591 Rev A 07 04 WIRING DIAGRAM 1 TRANSFORMER ...
Page 21: ...0900591 Rev A 07 04 Page 21 of 24 WIRING DIAGRAM 2 TRANSFORMER ...
Page 22: ...Page 22 of 24 0900591 Rev A 07 04 WIRING DIAGRAM EUROPEAN MODELS ...