P45000
30
6.9 Ambient Conditions
Installation site according to EN 50155
Enclosed control cabinet,
appendix C: 1 and 2
Height class
AX up to 2000 m above MSL (EN 50125)
Reduced isolation data for heights > 2000
…
4000 m above MSL
Temperature class
OT4/ST1/ST2 (+ 15 °C (59 °F)/10 min.) (EN 50155)
TX (EN 50125-1)
Class of rapid temperature change
H1 (to EN 50155)
Permitted temperatures
Single operation, air gap >15 mm (0.59
″
); OT4
for U
HE
/I
out
/R
M
:
at ±24 V/75 mA DC/0 Ω
-40
…
75 °C (-40
…
167 °F)
at ±24 V/75 mA DC/133 Ω
-40
…
85 °C (-40
…
185 °F)
at ±24 V/50 mA
rms
/0 Ω
-40
…
85 °C (-40
…
185 °F)
at ±15 V/75 mA DC/0 Ω
-40
…
85 °C (-40
…
185 °F)
Side by side operation; air gap < 15 mm (0.59
″
);
max. 3 devices
for U
HE
/I
out
/R
M
:
at ±24 V/75 mA DC/0 Ω
-40
…
55 °C (-40
…
131 °F)
at ±24 V/50 mA
rms
/0 Ω
-40
…
65 °C (-40
…
149 °F)
at ±24 V/75 mA DC/133 Ω
-40
…
70 °C (-40
…
158 °F)
at ±15 V/75 mA DC/0 Ω
-40
…
75 °C (-40
…
167 °F)
at ±15 V/50 mA
rms
/200 Ω
-40
…
85 °C (-40
…
185 °F)
Transport/storage
-50
…
90 °C (-58
…
194 °F)
Relative humidity (
operation, storage and transport)
Annual mean value
≤ 75 %
Continuous operation
15
…
75 %
Continuously for 30 days a year
75
…
95 %
Occasionally on the other days
95
…
100 %
Pollution degree
P45***K2***
1)
PD2
P45***K2*1*
1)
PD3A
2)
(only EN 50124-1)
6.10 Device
Weight
P45***K2*0*
1)
Without partition
Approx. 370 g
With partition
Approx. 390 g
P45***K2*1*
1)
Approx. 500 g
Screw tightening torques
M5 input terminals
3 Nm
Output screw terminals
0.6 Nm
Vertical on mounting plate 2 x M6
5 Nm
Horizontal on mounting plate 3 x M6
(max. 3 devices stacked)
3 Nm
1)
The individual product type can be determined from the order description, indicated on the narrow side of the
product (device front), and the product key.
2)
Also note the requirements under
Summary of Contents for P45000