22
Test voltage
4 kV AC input against output against power supply
Working voltage
3)
(basic insulation)
1000 V AC/DC with overvoltage category II and pollution
degree 2 according to EN 61010-1
For applications with high working voltages, take measures
to prevent accidental contact and make sure that there is
sufficient distance or insulation between adjacent devices.
Protection against
electric shock
Protective separation according to EN 61140 by reinforced
insulation according to EN 61010-1.
Working voltages up to 300 V AC/DC across input and
output and power supply with overvoltage category II and
pollution degree 2.
For applications with high working voltages, take measures
to prevent accidental contact and make sure that there is
sufficient distance or insulation between adjacent devices.
EMC
4)
Product family standard: EN 61326
Surge withstand
5 kV, 1.2/50 µs, according to IEC 255-4
Ambient temperature
Operation
Transport and storage
-10 to +70 °C
-40 to +85 °C
Power supply
22 to 230 V AC/DC ± 10 %,1 W, AC: 48 to 62 Hz, 2 VA
(overvoltage category II)
Design
Modular housing
See dimension drawings for dimensions
Type H1 with pluggable screw terminals