Diaphragm Vacuum Pumps UN012, UN024, UN036_I
Installation
7
Fig. 4: Electronic connection (.26-designs: with electronically-controlled
head heating)
Remove the protection plugs from the port threads.
Connect the suction and pressure lines. For size of the port
threads see section 9. For flow direction, see the marking on the
pump head or data sheet.
Arrange the suction and pressure lines so that condensate cannot
run into the pump (falling tubes).
Pneumatic