Technical data
Swing Piston vacuum pump NPK012
8
Translation of original operating and installation instruction, Englisch, KNF 316780-316783 05/19
Electrical data
Parameter
Value
NPK012
Voltage [V]
24
Frequency [Hz]
-
Power P
1
[W]
43
Max. current consumption [A]
1.8
Motor protection class
IP 20
Max. permissible mains voltage fluc-
tuations
See operating instructions for motor
Tab. 5
The pump is equipped with an overcurrent protection. If this safety
function is actuated, the pump is switched off and must be manually
reset:
à
Disconnect pump from mains.
à
Before switching back on, eliminate the cause of the error(s).
Weight
Pump type
Weight [kg]
NPK012
approx. 0.6
Tab. 6
Other parameters
Parameter
Value
NPK012PR
Value
NPK012VA
Permissible ambient temperature
[°C]
+ 5 to + 40
Permissible media temperature [°C] + 5 to + 40
Max. surface temperature* [°C]
+ 150
+ 120
Dimensions
See Chapter
Fig. 3
Highest permissible relative air hu-
midity of the environment
80% for temperatures to 31°C, de-
creasing linearly to 50% at 40°C.
Maximum installation altitude [m
above sea level]
2000
Protection class of pump
IP 00
Starts against:
- Pressure [bar gauge]
- Vacuum [mbar abs.]
5.0
220
1.0
140
Tab. 7 *Value measured at pump head
Summary of Contents for NPK012 Series
Page 27: ......
Page 28: ...KNF worldwide Find your local KNF partner on www knf com...