Diaphragm Liquid Pump NF 1.30
For your notes
KNF Flodos AG BA_NF1.30_EN_04_067674.docx
Translation of original Operating and Installation Instructions
7
Hydraulic ratings
Parameter
Value
Flow rate [ml/min]
1), 2)
170
Permissible pressure [bar g]
4
Suction head [mWG]
5
Tab. 4
1)
Measured with water at 20°C / at atmospheric pressure
2)
Flow rates may vary from the values shown, depending on fluid
viscosity, pump head material and the hoses / hose connectors
used.
Hydraulic connections
Parameter
Value
Recommended hose size ID [mm] / OD
[mm]
4/6
Tab. 5
Specifications NF 1.30 DCG
Motor voltage
12V
24V
Power consumption [W]
10.1
11
Max. I load [A]
0.61
0.35
Max. permissible operating
current [A]
0.84
0.46
Lead size [-]
AWG28
Protection class [-]
IP00
Weight
1)
[g]
220
Tab. 6
1)
The weight may differ slightly from the stated value, depending on
the version.
Other parameters
Parameter
Value
Permissible
ambient temperature range (°C)
+5 to +40
Permissible media temperature range (°C) +5 to +80
Permissible kinematic viscosity of medium
[cSt]
≤150
Tab. 7