KNF MOTOR M 56 EX
Servicing
Translation of Original Operating- and Installation Instructions, english, KNF 121220-121648 02/19 17
8. Servicing
Servicing schedule
WARNING
Danger of explosion due to wear!
Have motor bearings replaced by KNF Neu-
berger according to servicing schedule
(see table 10).
Component
Servicing interval
Motor bearings
-
Have them replaced after 17,000
operating hours or 24 months at the
latest
Lead-through, con-
nection or lead-in
parts
-
Inspect regularly
-
In case of damage, the damaged parts
must be replaced by original spare
parts in perfect order.
Tab. 10
Maintenance on the motor must be performed under ob-
servance of the relevant national regulations “Ordinance Con-
cerning Electrical Equipment in Potentially Explosive Areas” as
well as the safety advisories and descriptions in these instruc-
tions.
Components such as terminals, cable glands and plugs may
be replaced only by equivalent parts having the EC-Type Ex-
amination Certificate.