KNF FL 10 Installation Instructions Manual Download Page 8

Installation 

 

Installation Instructions FL 10  

 

KNF Flodos 173856_MA_FL10_EN_01.docx1 

8

 

3.4  Electrical connection 

For terminal assignment, output data, and control requirements, 
please refer to the data sheet 
Observe the regulatory requirements for electrical installations: 

  Overload protection and separating protective devices  

  Contact protection and additional insulation  

  Ground connections 

  Protection against vibrations, tensile stress, and corrosion 

3.4.1  DC coils 

 

 

CAUTION 

Danger from burns or fire, poisoning from flue gases 

If the pump is connected incorrectly, it may overheat and catch 
fire. 

  Connect the pump to the correct voltage 

  Operate the pump in accordance with the technical data 

  Take suitable precautions to limit maximum power con-

sumption. 

 

3.4.2  AC coils 

 

 

DANGER 

Danger from electric shock 

  Connect the pump to the correct voltage 

  Wear personal protective equipment 

  Operate the pump only when you are sure it has no tech-

nical malfunctions 

  Operate the pump in accordance with the technical data 

  Ensure that the fluid circulation system is grounded 

  Check the pump for damage regularly 

  Disconnect the pump from the power supply when carrying 

out maintenance work 

  In case of fixed installation, install a maintenance switch 

  Installation only by trained, skilled personnel who have 

knowledge of the applicable international regulations  

  Ensure contact protection for live parts (persons, cable, and 

device protection) 

 

 

 

Summary of Contents for FL 10

Page 1: ...FL 10 INSTALLATION INSTRUCTIONS DIAPHRAGM PUMP FL 10 DC P FL 10 AC Before operating the pump please read the Installation Instructions and safety precautions...

Page 2: ...1 5 Supporting documents 4 2 Safety 5 2 1 Intended use 5 2 2 Reasonably foreseeable misuse 5 2 3 Responsibility of the user 5 2 4 Product specific risks 5 3 Installation 7 3 1 Installation location 7...

Page 3: ...or PML there may be differences from the Installation Instructions 1 2 Warnings Warnings in the Installation Instructions are marked by the hazard symbol the keywords and the color These features pro...

Page 4: ...improper handling The manufacturer accepts no liability for damage or malfunctions that are caused by using spare parts or accessories that are not approved by the manufacturer 1 4 Manufacturer s add...

Page 5: ...warnings in this section and in the other sections of the Installation Instructions must be observed to prevent dangerous situations DANGER Danger of injuries and damage to property due to dangerous...

Page 6: ...mp in accordance with the technical data DANGER Danger of injuries and damage to property due to uncon trolled flow while the pump is not in operation Poisoning and chemical burns or unintended reacti...

Page 7: ...ion 3 1 Installation location The installation location must protect the pump against immersion keep aggressive and flammable liquids and vapors away allow hoses to be connected without tensile or ben...

Page 8: ...to the correct voltage Operate the pump in accordance with the technical data Take suitable precautions to limit maximum power con sumption 3 4 2 AC coils DANGER Danger from electric shock Connect the...

Page 9: ...al reactions with water Residues of water in the pump that come from testing in the factory may react with the transferred medium Before starting the pump for the first time rinse it with a medium tha...

Page 10: ...e a preventive preliminary filter Pump does not trans fer External valve is closed or filter is clogged or too small Check external valves and filter Connections or hoses are blocked Check connections...

Page 11: ...ertakes to repair the pump only under the condition that the customer provides a certificate of the pumped medium and cleaning of the pump For this purpose please follow the instruc tions on www knf c...

Page 12: ...www knf com...

Reviews: