KNF FL 10 Installation Instructions Manual Download Page 5

Installation Instructions FL 10  

Safety 

KNF Flodos 173856_MA_FL10_EN_01.docx1 

 

5

 

2  Safety 

2.1  Intended use 

The pump is intended solely for the following uses: 

  Transferring liquids and gases 

  For operation in accordance with the operating parameters 

specified in the technical data of the supporting documents 

2.2  Reasonably foreseeable misuse 

The pump must not: 

  be operated in an explosive atmosphere 

  be used to transfer explosive media 

  be used to transfer media whose compatibility with the pump 

head, valves, diaphragms, and seals has not been proven 

2.3  Responsibility of the user 

The user is responsible for ensuring that the safety precautions in 
these Installation Instructions are complied with. Applicable, safety, 
accident prevention, and environmental protection regulations must 
be complied with.  

2.4  Product-specific risks 

Remaining risks that were determined in a risk assessment are 
described in this section. Safety precautions and warnings in this 
section and in the other sections of the Installation Instructions 
must be observed to prevent dangerous situations.  

 

 

DANGER 

Danger of injuries and damage to property due to dangerous 
substances 

Poisoning and chemical burns or unintended reactions caused by 
leaking dangerous substances 

  Observe the safety data sheets of the transferred media 

  Before transferring a medium, check whether it can be 

transferred safely in the specific application case. 

  Ensure that the system is not subject to any risks of explo-

sion, also in extreme operating conditions (temperature, 
pressure) or in case of malfunctions. 

  Ensure the pump is used only by suitably trained, skilled 

employees 

  Clarify the wear resistance of the head material 

  Check that the pump and the system do not leak at the op-

erating temperature of the transferred medium 

  Regularly check the pump for damage 

  Operate the pump only when you are sure it has no tech-

nical malfunctions 

  Operate the pump in accordance with the technical data 

  Work on the pump or fluid circulation system only after they 

have been decontaminated and/or a decontamination decla-
ration is present 

 

 

 

Summary of Contents for FL 10

Page 1: ...FL 10 INSTALLATION INSTRUCTIONS DIAPHRAGM PUMP FL 10 DC P FL 10 AC Before operating the pump please read the Installation Instructions and safety precautions...

Page 2: ...1 5 Supporting documents 4 2 Safety 5 2 1 Intended use 5 2 2 Reasonably foreseeable misuse 5 2 3 Responsibility of the user 5 2 4 Product specific risks 5 3 Installation 7 3 1 Installation location 7...

Page 3: ...or PML there may be differences from the Installation Instructions 1 2 Warnings Warnings in the Installation Instructions are marked by the hazard symbol the keywords and the color These features pro...

Page 4: ...improper handling The manufacturer accepts no liability for damage or malfunctions that are caused by using spare parts or accessories that are not approved by the manufacturer 1 4 Manufacturer s add...

Page 5: ...warnings in this section and in the other sections of the Installation Instructions must be observed to prevent dangerous situations DANGER Danger of injuries and damage to property due to dangerous...

Page 6: ...mp in accordance with the technical data DANGER Danger of injuries and damage to property due to uncon trolled flow while the pump is not in operation Poisoning and chemical burns or unintended reacti...

Page 7: ...ion 3 1 Installation location The installation location must protect the pump against immersion keep aggressive and flammable liquids and vapors away allow hoses to be connected without tensile or ben...

Page 8: ...to the correct voltage Operate the pump in accordance with the technical data Take suitable precautions to limit maximum power con sumption 3 4 2 AC coils DANGER Danger from electric shock Connect the...

Page 9: ...al reactions with water Residues of water in the pump that come from testing in the factory may react with the transferred medium Before starting the pump for the first time rinse it with a medium tha...

Page 10: ...e a preventive preliminary filter Pump does not trans fer External valve is closed or filter is clogged or too small Check external valves and filter Connections or hoses are blocked Check connections...

Page 11: ...ertakes to repair the pump only under the condition that the customer provides a certificate of the pumped medium and cleaning of the pump For this purpose please follow the instruc tions on www knf c...

Page 12: ...www knf com...