KMS MD35 manual
Version 4.16
12
3.2.4.1.1
RPM pickup
In this menu, the settings for the RPM pickup signal, the type of ignition and the number of
cylinders can be entered.
RPM Range:
By clicking on the function you can set the rpm range for the main parameter maps (minimum rpm
is 500 and maximum is 20.000).
Standard the 25 rows are divided over a rpm range 12.500 rpm (example see left figure below). If
your engine doesn‟t make more than 6.500 rpm, you can devide the 25 rows over this 6.500 rpm
(example see right figure below). So the mapping will be more fine tuned for this engine rpm range.
3.2.4.1.1.1
Crank pickup
Users can enable the crank pickup and set the references.
Sensor type:
Here you can select if your connected sensor is hall or inductive.
Hall sensor: a current runs through a thin Hall-plate. When this plate is undergoing a magnetic field
a voltage arises between the two sides of the plate. When a tooth passes the plate the magnetic
field changes.
Summary of Contents for MD35
Page 1: ...MD35 Manual V4 16 ...
Page 72: ...KMS MD35 manual Version 4 16 72 Appendix 1 Trigger wheel drawings ...
Page 73: ...KMS MD35 manual Version 4 16 73 ...
Page 74: ...KMS MD35 manual Version 4 16 74 ...
Page 75: ......