KMC Controls STE-6014 Installation Manual Download Page 5

STE-6014/6017/6018/6019/6020 Room Temperature Sensors 

Installation Guide

NOTE:  In the Adobe Acrobat file of this document, you can select a table below to copy and paste the 

128 lines into the appropriate device table section of the BACstage *.BAC panel file.

X1=54.0
X2=54.3
X3=54.6
X4=54.9
X5=55.2
X6=55.5
X7=55.8
X8=56.1
X9=56.4
X10=56.7
X11=57.1
X12=57.4
X13=57.7
X14=58.1
X15=58.4
X16=58.8
X17=59.1
X18=59.5
X19=59.9
X20=60.3
X21=60.7
X22=61.1
X23=61.5
X24=61.9
X25=62.3
X26=62.7
X27=63.2
X28=63.6
X29=64.1
X30=64.5
X31=65.0
X32=65.5
X33=66.0
X34=66.5
X35=67.0
X36=67.5
X37=68.1
X38=68.6
X39=69.2
X40=69.8
X41=70.4
X42=71.0
X43=71.6

X44=72.2
X45=72.9
X46=73.5
X47=74.2
X48=74.9
X49=75.6
X50=76.3
X51=77.1
X52=77.8
X53=78.6
X54=79.4
X55=80.3
X56=81.1
X57=82.0
X58=82.9
X59=83.8
X60=84.8
X61=85.8
X62=86.8
X63=87.8
X64=88.9
X65=90.0
X66=90.0
X67=90.0
X68=90.0
X69=90.0
X70=90.0
X71=90.0
X72=90.0
X73=90.0
X74=90.0
X75=90.0
X76=90.0
X77=90.0
X78=90.0
X79=90.0
X80=90.0
X81=90.0
X82=90.0
X83=90.0
X84=90.0
X85=90.0
X86=90.0

X87=90.0
X88=90.0
X89=90.0
X90=90.0
X91=90.0
X92=90.0
X93=90.0
X94=90.0
X95=90.0
X96=90.0
X97=90.0
X98=90.0
X99=90.0
X100=90.0
X101=90.0
X102=90.0
X103=90.0
X104=90.0
X105=90.0
X106=90.0
X107=90.0
X108=90.0
X109=90.0
X110=90.0
X111=90.0
X112=90.0
X113=90.0
X114=90.0
X115=90.0
X116=90.0
X117=90.0
X118=90.0
X119=90.0
X120=90.0
X121=90.0
X122=90.0
X123=90.0
X124=90.0
X125=90.0
X126=90.0
X127=90.0
X128=90.0

NOTE:  These tables are NOT also for the STE-6012/6016.

X1=12.2
X2=12.4
X3=12.6
X4=12.7
X5=12.9
X6=13.1
X7=13.2
X8=13.4
X9=13.6
X10=13.7
X11=13.9
X12=14.1
X13=14.3
X14=14.5
X15=14.7
X16=14.9
X17=15.1
X18=15.3
X19=15.5
X20=15.7
X21=15.9
X22=16.2
X23=16.4
X24=16.6
X25=16.8
X26=17.1
X27=17.3
X28=17.6
X29=17.8
X30=18.1
X31=18.3
X32=18.6
X33=18.9
X34=19.2
X35=19.4
X36=19.7
X37=20.1
X38=20.3
X39=20.7
X40=21.0
X41=21.3
X42=21.7
X43=22.0

X44=22.3
X45=22.7
X46=23.1
X47=23.4
X48=23.8
X49=24.2
X50=24.6
X51=25.1
X52=25.4
X53=25.9
X54=26.3
X55=26.8
X56=27.3
X57=27.8
X58=28.3
X59=28.8
X60=29.3
X61=29.9
X62=30.4
X63=31.0
X64=31.6
X65=32.2
X66=32.2
X67=32.2
X68=32.2
X69=32.2
X70=32.2
X71=32.2
X72=32.2
X73=32.2
X74=32.2
X75=32.2
X76=32.2
X77=32.2
X78=32.2
X79=32.2
X80=32.2
X81=32.2
X82=32.2
X83=32.2
X84=32.2
X85=32.2
X86=32.2

X87=32.2
X88=32.2
X89=32.2
X90=32.2
X91=32.2
X92=32.2
X93=32.2
X94=32.2
X95=32.2
X96=32.2
X97=32.2
X98=32.2
X99=32.2
X100=32.2
X101=32.2
X102=32.2
X103=32.2
X104=32.2
X105=32.2
X106=32.2
X107=32.2
X108=32.2
X109=32.2
X110=32.2
X111=32.2
X112=32.2
X113=32.2
X114=32.2
X115=32.2
X116=32.2
X117=32.2
X118=32.2
X119=32.2
X120=32.2
X121=32.2
X122=32.2
X123=32.2
X124=32.2
X125=32.2
X126=32.2
X127=32.2
X128=32.2

Fahrenheit Values

Celsius Values

(Tables for BACstage *.BAC panel file)

Summary of Contents for STE-6014

Page 1: ...sunlight heat sources windows air vents and air circulation obstructions curtains furniture etc It can be mounted on a hollow wall or with a universal backplate HMO 6036 to a 2 x 4 inch handy box The...

Page 2: ...White 2 N C Lead 1 Orange White Cables crossed 20 AWG Wiring Connect wires as shown for the relevant model STE 6019 6020 Common Ground Thermistor 10k Ohms A B C Potentiometer Override Button D 10 VDC...

Page 3: ...ct Device Device Tables KMC10K Type II Table 10 Click Edit 11 Click Defaults values will fill in 12 Click End Edit 13 Click Yes for Send Update Notification Now 14 Click OK Setpoint Input 1 In the BAC...

Page 4: ...2 68 90 0 32 2 69 90 0 32 2 70 90 0 32 2 71 90 0 32 2 72 90 0 32 2 73 90 0 32 2 74 90 0 32 2 75 90 0 32 2 76 90 0 32 2 77 90 0 32 2 78 90 0 32 2 79 90 0 32 2 80 90 0 32 2 81 90 0 32 2 82 90 0 32 2 83...

Page 5: ...12 90 0 X113 90 0 X114 90 0 X115 90 0 X116 90 0 X117 90 0 X118 90 0 X119 90 0 X120 90 0 X121 90 0 X122 90 0 X123 90 0 X124 90 0 X125 90 0 X126 90 0 X127 90 0 X128 90 0 NOTE These tables are NOT also f...

Page 6: ...m pull up resistor jumper posi tion for the corresponding inputs See the Installa tion section of the BAC A1616ABC Building Control ler Installation and Operation Guide for the correct jumper position...

Page 7: ...00 54 12 2 2 0 32 58 14 4 3 0 77 62 16 7 4 1 14 66 18 9 5 1 47 70 21 1 6 1 74 74 23 3 7 1 97 78 25 6 8 2 16 82 27 8 9 2 31 86 30 0 10 2 42 90 32 2 11 5 00 90 32 2 15 Click OK WinControl Software Ther...

Page 8: ...Units which opens the Configure Variables screen 5 Select Type Digital 6 Select Off On or No Yes Stop Start Dis Enabled according to preference 7 Click OK 8 Click End Edit 9 Click OK Connections Clamp...

Reviews: