KMC Controls STE-6014 Installation Manual Download Page 1

STE-6014/6017/6018/6019/6020 Room Temperature Sensors 

Installation Guide

2.438

2.250

R 3.094

R .187

.643

STE-6019/6020

.475

max.

STE-6014/6017/6018

Modular 

RJ-45 

Jack

Four-pin 

EIA-485 
PC Data 

Port

Clamp

(Screw-type) 

Terminals

.422

Installation Guide

Room Temperature Sensors (with Rotary Dials) 

STE-6014/6017/6018/6019/6020

All dimensions are in inches

Hollow Wall Installation

1.  Remove the cover from the back panel.
2.  Using the back panel as a template, drill two holes 

for mounting screws (7/64 inches or 3 mm in di-

ameter and 1.4 inches, 1-13/32 inches, or 35.6 mm 

apart) and cut a center hole (size needed is depen-

dent on model) for the terminal block or jack.

3.  Attach the back panel to the wall using two 

#6 self-threading screws. (Plastic anchors are 

recommended, and the size of the holes will then 

need adjusting.)

4.  Attach the cable to the terminal block or jack 

according to the appropriate wiring diagram on 

the next page.

5.  Replace the cover.

Location and Cover Removal

Install the sensor on an inside wall where it can sense 

the average room temperature and be away from 

direct sunlight, heat sources, windows, air vents, 

and air circulation obstructions (curtains, furniture, 

etc.). It can be mounted on a hollow wall or (with a 

universal backplate HMO-6036) to a 2 x 4 inch handy 

box.
The cover is held to the black, back panel by three, 

small, round pegs that fit in the holes of the cover. 

The bottom peg is on a tab and snaps into the center 

bottom hole.

1.  With a small Phillips screwdriver or hex wrench, 

press in and hold the tab button that snaps into 

the center hole on the bottom cover.

2.  Carefully pull or pry the back panel from the 

front cover.

Handy Box Installation (Recommended)

1.  Mount a universal backplate 

HMO-6036 to the handy box 

using the two screws provided.

2.  Remove the cover from the 

back panel.

3.  Attach the back panel to the backplate using the 

two screws provided.

4.  Attach the cable to the terminal block or jack 

according to the appropriate wiring diagram on 

the next page.

5.  Replace the cover.

Mounting

STE-6014

STE-6018/6020

STE-6017/6019

NOTE:  Before July 2008, these models had 

numbered °F or °C dials.

Accessories

HMO-6036 

Universal Backplate

KMD-569

x

 

 STE-6010/6014/6015/6016/ 6017/ 

6018 to Controller Cable with RJ-

45 to RJ-11 Connectors (-569

3

 = 25 

ft.; -569

4

 = 50 ft.; -569

5

 = 75 ft.)

KMD-5624 

PC Data Port (EIA-485) Cable

KMD-5576 

EIA-485 to USB Communicator

Summary of Contents for STE-6014

Page 1: ...sunlight heat sources windows air vents and air circulation obstructions curtains furniture etc It can be mounted on a hollow wall or with a universal backplate HMO 6036 to a 2 x 4 inch handy box The...

Page 2: ...White 2 N C Lead 1 Orange White Cables crossed 20 AWG Wiring Connect wires as shown for the relevant model STE 6019 6020 Common Ground Thermistor 10k Ohms A B C Potentiometer Override Button D 10 VDC...

Page 3: ...ct Device Device Tables KMC10K Type II Table 10 Click Edit 11 Click Defaults values will fill in 12 Click End Edit 13 Click Yes for Send Update Notification Now 14 Click OK Setpoint Input 1 In the BAC...

Page 4: ...2 68 90 0 32 2 69 90 0 32 2 70 90 0 32 2 71 90 0 32 2 72 90 0 32 2 73 90 0 32 2 74 90 0 32 2 75 90 0 32 2 76 90 0 32 2 77 90 0 32 2 78 90 0 32 2 79 90 0 32 2 80 90 0 32 2 81 90 0 32 2 82 90 0 32 2 83...

Page 5: ...12 90 0 X113 90 0 X114 90 0 X115 90 0 X116 90 0 X117 90 0 X118 90 0 X119 90 0 X120 90 0 X121 90 0 X122 90 0 X123 90 0 X124 90 0 X125 90 0 X126 90 0 X127 90 0 X128 90 0 NOTE These tables are NOT also f...

Page 6: ...m pull up resistor jumper posi tion for the corresponding inputs See the Installa tion section of the BAC A1616ABC Building Control ler Installation and Operation Guide for the correct jumper position...

Page 7: ...00 54 12 2 2 0 32 58 14 4 3 0 77 62 16 7 4 1 14 66 18 9 5 1 47 70 21 1 6 1 74 74 23 3 7 1 97 78 25 6 8 2 16 82 27 8 9 2 31 86 30 0 10 2 42 90 32 2 11 5 00 90 32 2 15 Click OK WinControl Software Ther...

Page 8: ...Units which opens the Configure Variables screen 5 Select Type Digital 6 Select Off On or No Yes Stop Start Dis Enabled according to preference 7 Click OK 8 Click End Edit 9 Click OK Connections Clamp...

Reviews: