background image

5

MOD-TEK-100 - mounting instructions

b) Preparation of the OMODO-100 lighting fixture

www.KlusDesign.com

IIb

IIIb

5.

8.

9.

8.

9.

6.

2.1

Ib

1.2

2.2.

a.

 holes for locking bolts ø 2,5 mm / 0.1” 

item 

(1.2)

b.

 hole for a gland ø 6,5 mm / 0.26”

bottom view

7.

2.1

1.2

1.2

1.2

1.2

7.

2.1

top view

a.

 Drill holes for locking bolts in the 

profiled orientation line in the profile 

(2.1)

.

The number of holes must be equal 

to the number of bolts used. Each 

hole should be in the middle of the 

corresponding item 

(1.2)

. There must 

be a minimum of two bolts per 

1 meter of a profile.

b.

 Drill a hole in the profile 

(2.1)

 

for the cable gland.

NOTE!

 The profile 

(2.1)

 must be 

shortened by 6 mm / 0.24” at each end 

where the end caps will be mounted.

Adhere the LED tapes 

(5)

, mount 

the gland 

(6)

 and route the power 

cable through it.

Attach end caps to the item 2.1 

(8)

 

with the bolts 

(9)

.

Locking bolts 

(2.2)

 can be 

tightened preliminarily in the 

pre-drilled holes before mounting 

the profile at its destination 

(after mounting the LED tapes).

Run the power cable to the 

power supply through one of the 

channels in the profile 

(2.1)

so that it does not protrude 

above the surface.

Then connect it with the power 

supply 

(7)

.

Summary of Contents for MOD-TEK-100

Page 1: ... and related accessories can be found at www KlusDesign com Drawings of profiles and accessories in these instructions are simplified and only approximate the actual shapes Ref 18061 Ref 18053 1 1 1 2 2 1 1 3 2 2 4 5 8 9 6 7 11 10 12 3 13 1 1 RAM TEK 100 profile item 1 1 1 2 RAM TEK 100 profile item 1 1 1 3 Spring item 1 3 2 1 OMODO 100 profile item 2 1 2 2 Locking bolt 3 Drywall screw 4 End cap for it...

Page 2: ...3 4 Put the profile to the edge of the drywall panel Drill mounting holes through the panel and the profile s flange Maximum distance between the holes is 400 mm 15 75 NOTE The profile must not get deformed during mounting Insert the drywall screws 3 to pre drilled holes and tighten the profile s flange to the drywall with them Attach end caps for item 1 1 4 ...

Page 3: ...l holes in the second panel and the profile s flange Insert the drywall screws 3 into the pre drilled holes and tighten the second profile s flange to the drywall with them Place the second drywall panel against the profile Lead the power cable through the openings in the profile NOTE The profile must not get deformed during mounting ...

Page 4: ...e preparation using the RAM TEK 100 profile www KlusDesign com VIIa VIIIa IXa Apply plaster and make the surface even Smoothen the surface with sandpaper Prime and paint the surface Skip to pg 6 if assembled light fixture is received from factory ...

Page 5: ...tem 1 2 There must be a minimum of two bolts per 1 meter of a profile b Drill a hole in the profile 2 1 for the cable gland NOTE The profile 2 1 must be shortened by 6 mm 0 24 at each end where the end caps will be mounted Adhere the LED tapes 5 mount the gland 6 and route the power cable through it Attach end caps to the item 2 1 8 with the bolts 9 Locking bolts 2 2 can be tightened preliminarily in...

Page 6: ...OMODO 100 profile from falling out insert wedges temporarily 10 They should be inserted into the marked spots in the gap between item 1 1 and item 2 1 There should be one wedge for each marked element 1 2 and they should be placed from the side of the profiled orientation line Insert the OMODO 100 profile into the prepared mounting track To do so press the profile to the wall of the RAM TEK 100 from t...

Page 7: ...Vd VId optional 11 12 12 2 1 2 2 2 2 2 2 Secure the item 2 1 against slipping out by tightening the locking bolts 2 2 in the pre drilled holes Remove wedges and markings Attach the cover 11 by slightly bending the edge of the profile outwards Mount the optional silicone cords 12 ...

Page 8: ... Slightly bend the edge of the profile Hook the edge of the cover 11 with a flat tool and slide the tool along the single edge of the profile so the cover will snap out Do not bend the cover by force Remove the locking bolts 2 2 Slide the OMODO 100 profile towards the profiled orientation line and pull it down as shown in the figure ...

Reviews: