Sometimes, the machine will become disabled while it is self-testing or running. It may
display the Error Codes. Please look at following table:
1)
When troubleshooting, please operate in order of the listed solutions. If the
problem hasn’t be solved yet, please contact your supplier.
2)
After each troubleshooting, press
to return to the main interface.
3)
If the fault that is not listed occurs, please contact your supplier.
Troubleshooting
Error Code
Display Interface
Reason
Solution
ERROR 01
①
The self-test failed.
②
The signal of Alloy
Sensor is abnormal.
Please contact your
supplier.
ERROR 02
The infrared diode of
the Alloy Sensor is
abnormal.
①
Clean the infrared
diode of the Alloy
Sensor by tube brush.
②
Check the Alloy
Sensor cable.
ERROR 03
The Coin Drawer is
full of coins.
Replace or empty the
Coin Drawer.
ERROR 04
①
The Right Front
Cover
is
opened
while the machine is
running.
②
The Safety Switch
doesn’t work.
①
Close the Right
Front Cover.
②
Replace the Safety
Switch.