11
Category
II 2H 3B/P 220 - 230V AC - 50Hz
Nominal Pressure
LPG, 30-30mbar
NG, 20-20mbar
Rapid Burner
2,85 kw
(hs)
207 (g/h)
2,80 kw (hs)
0,264 (mᵌ/h)
Semi-rapid Burner
1,65 kw
(hs)
120 (g/h)
1,70 kw (hs)
0,166 (mᵌ/h)
Auxilary Burner
0,9 kw (hs)
65 (g/h)
0,95 kw (hs)
0,091 (mᵌ/h)
Big Triple Burner (3,8 kW)
3 kw (hs)
218 (g/h)
3,10 kw (hs)
0,278 (mᵌ/h)
Ø145 Hot Plate = 1000 W
Ø180 Hot Plate = 1500 W
Ø145 Hot Plate (Rapid ) = 1500 W
Ø180 Hot Plate (Rapid ) = 2000 W
Type of gas
Burner
Injector Marking
NATURAL GAS (NG)
G20-20mbar
Auxiliary
Semi-rapid
Rapid
Tripla Corona
0,72x
0,97z
1,15y
1,30 0
Liquid petroleum gas
(LPG) G30-30 mbar
Auxiliary
Semi-rapid
Rapid
Tripla Corona
0,5
0,65
0,85
0,9
Installation Instructions
Electrical connection
•
Make sure value of voltage and power cable is coherent with the label, before making
electrical connection.
•
If appliance will be connected directly to the mains, appropriate switch which has 3mm contact distance, up to
standards and appliance load, must be used. Don't use an adaptor and a switch to prevent overheating and fire.
•
Use earthed socket for feeder cable.
The manufacturer declines all liability for damage or injury resulting from: incorrect installation, improper,
incorrect or unreasonable use.
If the cable needs to be replace, you must use the cable, which is forbearing to heat and must be forbearing to
charge of applience and must by all means as the cable which is used by manufacturer 'scompany (T90C).You can
ensure this cable from authorized service.Also on the power cable's peak which is connected to the applience
must be occur yellow-green ground connection, which is larger 20mm than the others.
General Technical Properties