24
SOFT 80, SOFT 100 PELLET-BURNING STOVE
EN - Rev. 1.0
The table below indicates the settings with the relevant meaning:
Menu
Meaning
Settable values *
BOARD BEEPS
Enables/disables the beep sound on the power PCB
ON – OFF
BACKLIGHT ON
Regulates the duration of display illumination
2 – 10 sec
DISPLAY ON
Regulates the period the display remains ON
15 – 60 sec ON
BRIGHTNESS
Enables/disables the illumination of the display
ON – OFF
CONTRAST
Regulates the contrast of the display
15 – 60 #
KEY BEEPS
Enables/disables the beeps every time the remote control keys are pressed
ON – OFF
* The settings can affect the life of the batteries in the remote control.
Menu 06 – Initial load
Enables pellet pre-loading for 90 seconds when the appliance is switched off and cold. Start the function with button 1
(Increase) and stop it with button 3 (On/Off). This may be useful if the appliance is switched on after the tank has been
completely emptied, or when it is filled for the first time. Warning: once the operation has been completed, before
switching on the appliance you should empty any pellets left inside the ash box.
Menu 07 – Stove status
It allows for viewing the instantaneous status of the appliance, with the operating conditions of the various devices
connected to it. Several pages are displayed in succession. The data is reserved for Technical Assistance Centre.
The table below indicates the various devices with the relevant meaning:
Display wording
Meaning
L04-270218 (example)
Code of the firmware loaded in the control unit.
AIR 1.0 (example)
Code of the firmware loaded in the remote control.
T.SMOKE
Indicates the temperature measured by the probe inside the combustion chamber.
T.ROOM
Indicates the room temperature measured by the probe on the remote control.
T.ROOM 1
Indicates the temperature in ducted room 1 as measured by the probe, if there is one connected.
Indicates the status of the room thermostat, if there is one connected:
(OFF = R.T. contact OPEN = Thermostat not triggered);
(ON = R.T. contact CLOSED = Thermostat triggered).
T.ROOM 2
Indicates the temperature in ducted room 2 as measured by the probe, if there is one connected.
Indicates the status of the room thermostat, if there is one connected:
(OFF = R.T. contact OPEN = Thermostat not triggered);
(ON = R.T. contact CLOSED = Thermostat triggered).
ASP.RPM
Indicates the speed of the fume extractor.
LOAD
Indicates the pellet loading interval.
STATUS T.A.
Indicates the status of the main room thermostat.
(OFF = R.T. contact OPEN = Thermostat not triggered);
(ON = R.T. contact CLOSED = Thermostat triggered).
AIR SPEED
Indicates the speed of the front air fan.
DUCT. 1
Indicates the speed of the air in ducted room 1.
DUCT. 2
Indicates the speed of the air in ducted room 2.
TIMER 1
Indicates the end (in minutes) of the current operating phase.
TIMER 2
Indicates the end (in seconds) of the current operating phase.
ALARM DELAY
In the event of an alarm, it indicates the time (in seconds) after which the alarm appears on the display.
T.MOTHERBOARD
Indicates the temperature measured by the probe inside the control unit.