24
Cleaning carriage positioned in the centre of the rail:
Check the step sensor in the rotor (switching distance)
Rotate the magnet in front of the sensor and measure whether there is 24 Volt DC between the blue and black.
If not, replace the sensor.
check the timing belt
Check the rotor regulator:
is there a fault?
is the regulator released?
is the mains voltage present?
In case of power failure:
If the power supply to the AS2 is interrupted while cleaning, an error message is generated when the
power is switched back on.
This can be reset in one of two ways:
The error message is acknowledged by setting the start command again and the cleaning slide automatically resets
to the start position. When this has been done, cleaning can be restarted.
By pressing the 3-button combination ( ) under the display. It must then be reset to the start
position using the keyboard. Once this has been done, it is ready to start cleaning again.
Caution:
The AS2 has a resettable fuse in the control circuit. It can be reset by briefly disconnecting the AS2 from the
power (approx. 1 min.).
C l e a n i n g i n t e r r
E r r o r