User's Manual
LINE 212-6 / LINE 212-9
KLING & FREITAG GMBH ©2003 - 2005
Version 4.1, 23.03.2006
Seite 27 von 37
12.
Crossovers
12.1
Wiring Diagram
FUSE :
250 V T 4A
FUSE :
250 V T 4A
1-
1+
2+
2-
1-
1+
2+
2-
+
+
-
-
+
+
-
-
HF
HF
LF 1
LF 1
LF 2
LF 2
+
+
-
-
Pin assignment Speakon NL4
+ - / /
'IN'
1+ 1-
2+ 2-
'OUT'
parallel with 'IN'
12.2
Fuses and Protection Circuits
The LINE 212 is equipped with protection circuits, which cut off the signal current when
highly overloaded - for the 1.5" high frequency speaker as well as for the crossover. If
the high frequency speaker of the Line 212 turns off, reduce the volume. After a few
seconds, it will turn back on automatically.
If there is operating trouble, the low-mid crossover circuits are protected with fuses.
Blown fuses can only be replaced with fuses with the following specifications:
250V T4L (DIN EN 60127-2-3)
Do not use fuses with different specifications and do not try to bypass the fuse as this
may cause fire hazard.
Warning
O