background image

User’s Manual 

LINE 212-6 - SP / LINE 212-9 - SP 

KLING & FREITAG GMBH ©2003 - 2006   

Version 4.1, 19.06.2006 

Page 40 of 45 

 

19.

 

Regulations for Disposal 

 

19.1 

 

Germany: 

It is not allowed to dispose of used electrical equipment as domestic waste.   

But please do not dispose of them at official collecting points for recycling either! 
All Kling & Freitag products are plain business-to-business (B2B) products. Disposal of  
Kling & Freitag products labelled with a waste bin sign have thus to be disposed of by  
Kling & Freitag alone. Please call Kling & Freitag at the number stated below if you have 
a Kling & Freitag product to be disposed. We will offer you a straightforward and pro-
fessional disposal not affecting costs.  
If there is no dustbin sign on one of your Kling & Freitag products, because they have 
been sold before March 2006 then by law the owner is in charge of the disposal. For 
these we will be happy to assist and offer you proper ways of disposal. 

Telephone number to call about the disposal of used Kling & Freitag products:  
+49 (511)-96 99 7-0 

Explanation: 
With the ElektroG (law relating to electrical and electronic equipment and appliances) 
we have complied with the EU-directive on waste electrical and electronic equipment 
(WEEE, 2002/96/EC) 
The Kling & Freitag AG has thus labelled all products mentioned in the WEEE from 
03/24/2006 onwards with a sign with a crossed out waste bin and a white bar below. 
This sign indicates that the disposal into the domestic waste is prohibited and that the 
product has been put into circulation at the 03/24/2006 earliest.   
The Kling & Freitag GmbH has been legally registered as a manufacturer with the regis-
tration office EAR. Our WEEE Registration-Nr. is: DE64110372 
For the German Registration office EAR we have accredited that our products are sole  
B2B products. 

    

19.2 

 

EU, Norway, Island, and Liechtenstein (not Germany): 

It is not allowed to dispose of used electrical equipment as domestic waste.   

The Kling & Freitag AG has thus labelled all products coming from EU-Member coun-
tries as well as Norway, Island and Liechtenstein (except Germany) mentioned in the 
WEEE from 08/13/2005 onwards with a sign with a crossed out waste bin and a white 
bar below. This sign indicates that the disposal into the domestic waste is prohibited 
and that the product has been put into circulation at the 08/13/2005 earliest.   
Unfortunately the European directive WEEE has been complied with implementing 
different national provisions of law throughout all member countries, which makes it 
impossible for us to offer consistent solutions for the disposal throughout Europe.  
Responsible for complying with these provisions of law is the local distributor (importer) 
of each country.  
For proper disposition of used products in accordance with these local provisions in 
the mentioned countries of the European Union (except Germany) please ask your 
local dealer or the local authorities.  

19.3 

 

Other countries 

For proper disposition of used products in accordance with local provisions in other 
countries please ask your local dealer or the local authorities.  

 

 

 

Summary of Contents for LINE 212-6-SP

Page 1: ...GmbH Junkersstrasse 14 D 30179 Hannover TEL 0 049 511 969 97 0 FAX 0 049 511 67 37 94 www kling freitag de User s Manual Important Information Please Read Before Use KLING FREITAG GmbH Junkersstrasse...

Page 2: ...User s Manual LINE 212 6 SP LINE 212 9 SP KLING FREITAG GMBH 2003 2006 Version 4 1 19 06 2006 Page 2 of 45...

Page 3: ...ing these instructions may cause minor injuries or cause property damage Important This symbol gives instructions for the proper use of the described prod ucts Not following these instructions may cau...

Page 4: ...e Power Connectors to the Connecting Terminal 24 11 Configurations and Connecting Diagrams 25 11 1 Operating the Systems without C2 Controller 25 11 1 1 Full Range Mode 25 11 1 2 Full Range Mode with...

Page 5: ...e centre If the unit is not compatible with the available voltage it should never be connected This could irreparably ruin the SP speaker Make sure that the power outlet supplies a ground connector wh...

Page 6: ...lifting and aligning the speakers Never hang more than two speakers under one another without using the designated Kling Freitag rigging equipment Ensure that all installation connections comply with...

Page 7: ...g the K F C2 Controller are also possible which is for example appropriate for combined applications with equivalent passive systems or for the use of C2 presets clustering Top Low Cut Bass Boost etc...

Page 8: ...eb FDS 366 336 334 and XTA DP 226 224 K F sys tem parameters are available upon request The operation of the K F SP models with Controller C2 or Audio DSP is recom mended for uses in which special fil...

Page 9: ...ntegrated amplifier module The ground connection between LINE IN XLR male and LINE OUT XLR female is main tained The use of the Ground Lift switch is sometimes necessary in dealing with hum problems s...

Page 10: ...espec tive volume levels between the top speakers and the bass systems are correctly balanced To this end the sound engineer should check the volume levels during the set up and adjust them accordingl...

Page 11: ...bility with all K F speak ers operating in conjunction with the K F C2 Controller in the 2 way active mode is guaranteed 6 LED POWER ON GREEN and LIMIT PROTECT RED The LED is dual purpose a When the L...

Page 12: ...D is red Fault Measure Function LED remains red or flickers continually during opera tion Reduce output level on mixer until the LED goes out or flickers only occasion ally Limiter No output signal LE...

Page 13: ...ucted ready for use power cord is included in the delivery For deliveries to foreign countries a pre constructed power cord incl PowerCon plug is included Because of the different standards abroad the...

Page 14: ...inde pendent of one another Furthermore the sys tems no matter if individual or connected to one another must be secured onto the allsafe JUNGFALK flying track on the rear This safety rope may be use...

Page 15: ...shackles with a cotter pin Only in this way can you ensure that the bolt will not become loose The allsafe JUNGFALK flying track can only support weights up to 73 kg Therefore the load must be distrib...

Page 16: ...ceptacle for special fasteners 1 2 Take the single stud fitting in one hand and push the locking device up against the spring tension 3 4 Put the flat head of the holding bolt into the guiding of the...

Page 17: ...tud Fitting Used as fastener to the allsafe JUNGFALK Flying Point and the allsafe JUNGFALK Flying Track allsafe JUNGFALK Flying Track Receptacle for special fasteners such as the single stud fitting 1...

Page 18: ...as fastener to the allsafe JUNGFALK Flying Point and the allsafe JUNGFALK Flying Track allsafe JUNGFALK Flying Track Receptacle for the double stud fit ting 1 2 Align the double stud fitting as shown...

Page 19: ...e angle is possible by only removing the upper section of the grille To turn the horn follow these steps 1 Disconnect the power plug 2 Make sure that no objects fall into the enclosure 3 Remove the fo...

Page 20: ...er Arrangement of the Loudspeakers Be aware of the fact that the logical targeted alignment of this high quality speaker system can lead to a significant qualitative increase in the acoustic result It...

Page 21: ...to have a horizontal array angle of 38 5 to one another see fig 2 2 In a cluster comprised of a combination of the Line 212 6 with Line 212 9 we recommend an array angle of 45 see fig 3 3 With a rotat...

Page 22: ...15E Other combinations of Line 212 Systems are not recommended as they can cause un wanted interferences Horn Horn Horn Horn not not not not rotated on rotated on rotated on rotated on standing Line 2...

Page 23: ...connected then set the Ground Lift switches on the rear of the SP speakers to the Lift position chap ter 3 section 2 If the noise is still audible check if 1 the noise is caused by a ground loop befo...

Page 24: ...03 2006 Version 4 1 19 06 2006 Page 24 of 45 10 2 Connecting the Power Connectors to the Connecting Terminal 2 1 3 1 2 Only use the supplied power cable and connect it to a mains outlet with a 16 A fu...

Page 25: ...igh bass content Should more bass be needed the bass level can be increased be tween 50 and 80 Hz at the mixing console The switch FILTERS on The switch FILTERS on The switch FILTERS on The switch FIL...

Page 26: ...ker must be at the SP speaker must be at the SP speaker must be at ON in this mode ON in this mode ON in this mode ON in this mode If you need a high boost for covering larger distances compensation o...

Page 27: ...s have their own limiters The countersunk switch Full Range Mode on the C2 Controller should be pressed and the LED assigned to it should light up The full range switch increases the bass frequen cies...

Page 28: ...gh systems in a cluster speakers in close proximity press the Top Low Cut switch on the C2 Controller CHANNEL 2 LINK CHANNEL 2 IN CHANNEL 1 IN CHANNEL 1 LINK CH2 SUB AMP REMOTE CONTROL 240V 50Hz CE FU...

Page 29: ...manufacturer s recommendations can be found take the output impedance of the signal source In this case we recommend a total input impedance at least 10 times higher than the stated output impedance...

Page 30: ...0 1 Next turn up the C2 Controller if used and all other peripheral units and check these for interference Your system should now be ready for operation You can now turn up the level on the mixer If y...

Page 31: ...INPUT UNIT FILTERBOARD LINE 212 PHASE CORRECTION LINE 212 SP AMPLIFIER UNIT 1 HI PASS GAIN 6 dB FILTERS ON OFF HF CORRECTION ERROR CONTROLLER LIMITER RMS PEAK THRESHOLD PEAK THRESHOLD RMS HI PASS GND...

Page 32: ...input and 1 output Input module Input module Input module Input module Signal connectors Pin 1 ground pin 2 signal pin 3 signal LINE IN XLR 3 pin female LINE OUT XLR 3 pin male parallel with LINE IN I...

Page 33: ...put Input module Input module Input module Input module Signal connectors Pin 1 ground pin 2 signal pin 3 signal LINE IN XLR 3 pin female LINE OUT XLR 3 pin male parallel with LINE IN Input sensitivit...

Page 34: ...12 6 SP Frequency response on axis Beamwidth 20 6dB Beamwidth degrees 100 1000 10000 20000 Frequency Hz 0 60 120 180 240 300 360 Horizontal Vertical Q Index 20 20 100 1000 10000 20000 1 10 100 Directi...

Page 35: ...zontal coverage pattern 125 250 500 1k 2k 4k 8k 16K 180 150 120 90 60 30 0 30 60 90 120 150 180 f Hz 0 3 3 0 6 3 9 6 12 9 15 12 18 15 18 Vertical coverage pattern 125 250 500 1k 2k 4k 8k 16K 180 150 1...

Page 36: ...ncy response on axis Beamwidth 20 6dB Beamwidth degrees 100 1000 10000 20000 Frequency Hz 0 60 120 180 240 300 360 Horizontal Vertical Q Index 20 20 100 1000 10000 20000 1 10 100 Directivity Factor Q...

Page 37: ...tal coverage pattern 125 250 500 1k 2k 4k 8k 16K 180 150 120 90 60 30 0 30 60 90 120 150 180 f Hz 0 3 3 0 6 3 9 6 12 9 15 12 18 15 21 18 Vertical coverage pattern 125 250 500 1k 2k 4k 8k 16K 180 150 1...

Page 38: ...on 4 1 19 06 2006 Page 38 of 45 17 Dimensions 8 740 222 mm 16 890 429 mm ANCRA Jungfalk 0 033 10 mm 39 961 1015 mm 120030 31 Kunststoff f e Flugpunkte 510 mm 20 079 Stapel mulden 8 450 214 6 mm Flugsc...

Page 39: ...1 19 06 2006 Page 39 of 45 18 Accessories for the LINE 212 System Click Fly Connector 30 Connector 38 5 Connector 45 Quick Release Pin Application examples Click Fly LINE 212 Single Stud Fitting Doub...

Page 40: ...into the domestic waste is prohibited and that the product has been put into circulation at the 03 24 2006 earliest The Kling Freitag GmbH has been legally registered as a manufacturer with the regis...

Page 41: ...own responsibility that the products Kind of equipment Loudspeaker systems with integrated amplifier s Type designation CA 1001 SP CA 1201 SP CA 1215 6 SP CA 1215 9 SP CA 1515 6 SP CA 1515 9 SP LINE 2...

Page 42: ...User s Manual LINE 212 6 SP LINE 212 9 SP KLING FREITAG GMBH 2003 2006 Version 4 1 19 06 2006 Page 42 of 45 20 2 EMV Certificate Directive 89 336 EWG...

Page 43: ...User s Manual LINE 212 6 SP LINE 212 9 SP KLING FREITAG GMBH 2003 2006 Version 4 1 19 06 2006 Page 43 of 45...

Page 44: ...User s Manual LINE 212 6 SP LINE 212 9 SP KLING FREITAG GMBH 2003 2006 Version 4 1 19 06 2006 Page 44 of 45 20 3 T V Certificate for the USA and Canada UL 6500...

Page 45: ...User s Manual LINE 212 6 SP LINE 212 9 SP KLING FREITAG GMBH 2003 2006 Version 4 1 19 06 2006 Page 45 of 45...