27
24.05.2019
Filtering unit
UFO-A-5000
The impurities
are
separated (by
the
pneumatic impulses) from
the
filter surface. Subsequently
they fall through the discharge hopper chamber into the waste container. The waste container
must be emptied systematically.
Periodically,
the
pneumatic installation
of filters
regeneration ought
to be
dewatered by opening
the discharge valve.
The condensate water (dripping) must be discharged
from
the
system. Subsequently, close
the
dewatering valve at the moment when the discharging air is
clean
and
dry
.
The construction of the
extraction fan and
motor
guarantees the
work of the unit
without the rou-
tine everyday technical maintenance. In case when defective function of the device is noticed,
submit the device to technical revision (see Section 8).
Any repair activity and technical revisions are admissible to be carried
out exclusively after the device is disconnected from the power supply system.
8. Troubleshooting Guide
Table No.3
Problem
Possible reason
Corrective action
1
. Dust particles are emer-
The cartridge filter is faulty
Replace the defective filter
ging outside the device
Defect or deformation of the
Replace the faulty sealing
– observed after a period of sealing (gasket) of the cartridge
correct functioning of the
device
filter.
2
. Dust is emerging outside
The cartridge filter has got
Replace the faulty cartridge
the appliance
defective or released/untight
filter or correct its mounting
Another (as mentioned in the instru- Contact the manufacturer
ction) sort of the dust is noticed
Low filtration efficiency
Contact the manufacturer
3
. Decrease of air volume
Filters regeneration proceeds
Correct the air pressure to
flow efficiency
– observed incorrectly – due to too low pressure the value of 0,6 – 0,8 MPa
after a period of correct
of the external compressed air
in the air supply system.
functioning of the device
The cleaning time and work time
Correct the settings of the
are not adjusted appropriately.
micro-controller operation ac-
cording
to the present manual
Too high humidity of the filters, cau- Dewater the compressed air
sed by the humid compressed air
tank, examine the state of
from the external installation
the compressed air system
Dust is emerging outside
– due to
Limit the temperature of
temperature higher than +40
C of
the inlet air
the inlet air
9. Maintenance
9.1 Cartridge filters
Upon every emptying of the waste container (under the hopper), examine visually the state of
the cartridge filters. First disconnect the power supply.
Through the front revision door, check the mounting correctness of
the elements
, the state of
the filtration surface, pollution degree, search for failures, etc.