background image

 

                               18 

 

                                               

RADIAL  ROOF  FANS

  SMART-N                                      31.05.2019 

   

 

 

13.

 

Sample of the Declaration of Conformity 

 

 

 

Declaration 

of conformity EC No. …………….. 

Manufacturer (eventually the authorized representative / importer): 
name:  

KLIMAWENT  S.A.

 

address:  

81-

571 Gdynia,  Chwaszczyńska 194

  

 

A person, authorized for issuing the technical documentation:  

Teodor Świrbutowicz,  KLIMAWENT S.A. 

 

hereby declares that the appliance: 
name:   

Radial roof fan

 

 

type/model: 

SMART-N

 

serial number:  ……………………………..  year of production:  ……………………….. 

 

meets the requirements of the subsequent European Directives:

 

 

 

2006/42/EC

 

Machinery Directive

  

of the European Parliament and of the Council of 17 May, 2006  on machinery  

– amending the 95/16/EC (recast) /

Journal of Laws EC L157 of 09.06.2006, page 24

 

2014/35/EC Directive 

of the European Parliament and of the Council of 26 February, 2014  on the harmonisation 

of the laws of the Member States  relating to the making available on the market of electrical equipment designed 
for use within certain voltage limits. /

Journal of Laws EC L96  of 29.03.2014

The appliance meets the requirements included in: 

 

2009/125/EC (ErP)

 

Directive 

of the European Parliament and of the Council of October 21

th

, 2009 establishing a 

framework for the setting of ecodesign requirements for energy-related products /

Journal of Laws L 285 of 31.10.2009

/

 

 

327/2011

 (

EU

Guideline 

of March 30

th

, 2011 on implementing the 

2009/125/EC Directive

 of the European Parlia-

ment and of the Council with regard to ecodesign requirements for fans driven by motors with an electric input po-  
-wer between 125W and 500 kW  /

Journal of Laws L No. 90  of 06.04.2011

/

 

The device has been constructed and produced on the basis of following harmonized standards: 
● 

EN ISO-12100:2012 

 
 

 

“Safety of machinery. Basic concepts, general principles  

 

 

 

for design.  Risk assessment and risk reduction” 

● 

EN 60204-1:2018-12

 

 
 

 

“Safety of machinery – Electrical equipment of machines.  

 

 

 

Part 1:  General requirements” 

● 

EN 60034-1:2011 

 
 

 

“Rotating electrical machines  –  Part 1:  Rating data and  

 

 

 

pa

rameters” 

● 

EN ISO 5802:2008/A1:2015-07

 

 
 

 

“Industrial Fans – Performance testing in situ of installing  

● 

EN ISO 13857:2010 

 
 

 

“Safety 

of

 machinery

 

  

  Safe distances 

to

 prevent hazard  

 

 

 

zones being reached by upper and lower limbs”. 

 

…………………………… 

…………………………… 

…………………………… 

place, date 

signature of authorised person 

name, surname, function 

 

 

of the signatory 

 

KLIMAWENT  S.A. 

District Court Gdańsk-Północ 

NIP:  958 159 21 35 

Supported Employment Enterprise 

in Gdańsk,  VII Wydział Gospodarczy 

REGON:  220631262 

81-571 Gdynia, 

ul. Chwaszczyńska 194

 

of the National Register of Court 

Bank Account:  

Santander Bank Polska S.A. 

phone: +49 58 829 64 80 

KRS 0000308902  company stock 

56 1500 1025 1210  2007 8845 0000 

email:  

[email protected]

 

13.779.200 zł paid in total 

 

www.klimawent.com.pl

   

 

 

 
 

 

Summary of Contents for SMART-160/3000-N

Page 1: ...812W70 SMART 400 750 N 31 05 2019 EN 812W61 SMART 200 1000 N 31 05 2019 EN 812W71 SMART 400 1000 N 31 05 2019 EN 812W62 SMART 200 1500 N 31 05 2019 EN 812W72 SMART 400 1500 N 31 05 2019 EN 812W63 SMA...

Page 2: ...of March 30th 2011 on implementing the 2009 125 EC Directive of the European Parliament and of the Council with regard to ecodesign requirements for fans driven by motors with an electric input power...

Page 3: ...ional use 4 Technical Data Table No 1 Type of the fan Synchronous rotations Supply voltage Motor rate Maximum volume flow Maximum fan pressure Weight r p m V Hz kW m h Pa kg SMART 160 3000 N 3000 3 x...

Page 4: ...2019 Flow charts Table No 2 SMART 160 3000 N Acoustic pressure level dB A outlet inlet 1 m 5 m 10 m 15 m 1 m 79 69 62 59 71 Table No 3 SMART 200 1000 N Acoustic pressure level dB A outlet inlet 1 m 5...

Page 5: ...sure level dB A outlet inlet 1 m 5 m 10 m 15 m 1 m 79 69 62 59 71 Table No 4 SMART 250 1000 N Acoustic pressure level dB A outlet inlet 1 m 5 m 10 m 15 m 1 m 65 56 48 44 53 SMART 250 1500 N Acoustic p...

Page 6: ...oustic pressure level dB A outlet inlet 1 m 5 m 10 m 15 m 1 m 68 59 51 48 59 SMART 315 1500 N Acoustic pressure level dB A outlet inlet 1 m 5 m 10 m 15 m 1 m 80 70 63 60 70 SMART 315 3000 N Acoustic p...

Page 7: ...ustic pressure level dB A outlet inlet 1 m 5 m 10 m 15 m 1 m 63 55 46 43 53 SMART 400 1000 N Acoustic pressure level dB A outlet inlet 1 m 5 m 10 m 15 m 1 m 73 62 56 52 62 SMART 400 1500 N Acoustic pr...

Page 8: ...MART N 31 05 2019 Table No 7 SMART 500 750 N Acoustic pressure level dB A outlet inlet 1 m 5 m 10 m 15 m 1 m 69 59 52 49 61 SMART 500 1000 N Acoustic pressure level dB A outlet inlet 1 m 5 m 10 m 15 m...

Page 9: ...ROOF FANS SMART N Table No 8 SMART 630 750 N Acoustic pressure level dB A outlet inlet 1 m 5 m 10 m 15 m 1 m 77 67 60 56 70 SMART 630 1000 N Acoustic pressure level dB A outlet inlet 1 m 5 m 10 m 15 m...

Page 10: ...a motor with a radial impeller Impeller is statically and dynamically balanced according to ISO 14694 2003 AMD1 2010 gaining the G 2 5 class Lower skeletons of the 3000 r p m synchronous rotation fans...

Page 11: ...fans of 3000 r p m Fig No 1 Fans of SMART N types structure and dimensions Table No 10 Dimensions of the fans type SMART N except for fans of rotational speed 3000 r p m Type of the fan A B C D E Qua...

Page 12: ...on a roof of the industrial building it is important to install it on a pedestal with a suitable roof base It is recommended to apply the TPD N or TPDC N sound absorbing roof bases delivery on separat...

Page 13: ...and positioned at the place of operation Connection flange Fig No 3 Connection flange of the fan dimensions Table No 12 Dimensions of the connection flanges Type of the fan Connection flange A mm B mm...

Page 14: ...C 160 N 160 430 630 625 SMART 200 N TPDC 200 N 200 430 630 625 SMART 250 N TPDC 250 N 250 530 730 950 SMART 315 N TPDC 315 N 315 530 730 950 SMART 400 N TPDC 400 N 400 790 990 1200 SMART 500 N TPDC 50...

Page 15: ...the fan even for a check before the hood is reinstalled CAUTION 1 Insulation class I 2 Ingress protection IP54 3 Setting of the motor protective switch Q1 It 1 1 x In where In means rated current o th...

Page 16: ...egular periods of time i e once a year During the check take into account the function of the fan as well as its technical state All the activities connected with technical revisions on the fan have t...

Page 17: ...t be neither thrown nor knocked down Do not put any additional load on the device It is inadmissible to put one device on top of another no stacking During the transport protect them from atmospheric...

Page 18: ...s Journal of Laws L 285 of 31 10 2009 327 2011 EU Guideline of March 30th 2011 on implementing the 2009 125 EC Directive of the European Parlia ment and of the Council with regard to ecodesign require...

Page 19: ...19 31 05 2019 RADIAL ROOF FANS SMART N NOTES...

Page 20: ...20 RADIAL ROOF FANS SMART N 31 05 2019 NOTES...

Reviews: