![Klimawent ERGO-KOS-AL Use And Maintenance Manual Download Page 2](http://html1.mh-extra.com/html/klimawent/ergo-kos-al/ergo-kos-al_use-and-maintenance-manual_1977936002.webp)
2
extraction rail
ERGO-KOS-AL
30.01.2019
1.
Introductory Remarks
The purpose of the present
Use
and Maintenance Manual is to supply User with directions wi-
thin the range of application, installation, start-up and the use of the
ERGO-KOS-AL
extrac-
tion rail
.
Installing, start up and operational use are exclusively admissible after getting acquaint-
ted with the contents of the Use and Maintenance Manual
.
With regard to continuity of work carried on
improvement
of our
products, we reserve for oursel-
ves the revision possibility of the
draft and
technological changes improving their functional
features and safety.
Construction of the
ERGO-KOS-AL
extraction rail
meets
the
requirements of the current state
of
technology
as well as the safety and health assurances included in:
2006/42/EC
Machinery Directive
of the European Parliament
and of the Council of
May 17
th
,
2006 on machinery
– amending the 95/16/EC (recast)
/
Journal of Laws EC L157 of 09.06.2006, page 24
/
Additionally, the appliance meets following harmonized standard:
●
EN ISO-12100:2012
–
“Safety of
machinery
–
Basic concepts, general
principles
for design. Risk assessment and risk reduction”
2.
Application
ERGO-KOS-AL is designed for extraction of welding fumes at mobile workplaces
– for linear wel-
ding of elements of length up to several metres. The system can work with one or two extraction
fans, depending on the quantity of extraction arms (one extraction arm is subordinated to one
fan).
3.
Reservations of Producer
A
.
Manufacturer accepts no liability
for any consequences following from the operational use
that is in contradiction to the purpose of application.
B
.
Installing of
any additional elements not belonging to the normal device structure (
or acces
-
sory set) is not acceptable.
C
.
Do not undertake
any structural changes or constructional modifications on the device on
one
’s own.
D
.
Protect the flexible elements and the suction ducts from mechanical damage.
E
.
Prior to installing, check the load carrying capability of the building structure where the sys-
tem will be mounted. Unstable installing can result in uncontrolled device detachment and
hazard to personnel / people in the vicinity.
4.
Technical Data
Table No.1
Self-tightening suction duct
Type
Part. No
Segment
length
[m]
Cross-
section
[cm²]
Unit weight
[kg/m]
KOS-AL
804K08
2 or 4
290
9,7
Trolley
Type
Part. No
Weight
[kg]
OP-ERGO-L
851W10
9