BIG-5000-Ex filtering unit can be installed, exclusively in areas classified as 22, or in areas not featuring 
explosive hazard

.  

According to the ATEX 137 Directive, User has to determine the environment where 

the appliance shall be used

.

 

 

 

RESERVATIONS  OF  MANUFACTURER 

3.1    Manufacturer  is  not  responsible  for  damages  /  malfunctions  being  caused  as  a  result  of  reasons 
mentioned below

 

Any consequences following from the installing that is in contradiction to the present Use and Maintenance 
Manual. 

 

Situations  where  the  appliance  is  connected  to  the  electrical  power  supply-  or  the  pneumatic  system 
incorrectly. 

 

Operational use that is in contradiction with the present Use and Maintenance Manual and its specified 
purpose. 

 

Installing of any additional elements  that are not belonging  to the normal device structure (or accessory 
set) is not acceptable. 

 

Introduction of any structural or constructional modifications of the system on 

one’s own. 

 

Situations when the principles of control and maintenance of the appliance are not observed. 

 

Forwarding of the air containing viscous and aggressive impurities or of the air temperature exceeds 40

what might result in damage of the filters. 

 

3.2 

In the course of operational use, it is important to prevent ignition sources (i.e. sparks, cigarette 
butts / embers) from getting into the filtering unit. 

 

 

3.3 

Operator should wear antistatic clothes while emptying the waste container, during the technical 
inspection, maintenance and during any other activities near the filtering unit. 

 

 

3.4 

Do not use mobile phones and devices emitting electromagnetic waves close to the filtering unit 
and in the vicinity. 

 

 

3.5 

At the side of decompression panel 

– it is important to create a hazard area of potential explosion 

according to the Fig. No.7.  This area should be free of barriers such as machines, devices, walls 
etc.  

 

 

3.6 

In  case  when  explosion  hazard  exists  within  the  whole  installation,  (where  the  filtering  unit  is 
installed),  User  should  carry  out  the  total  risk  evaluation,  with  reference  to  the  being  valid 
regulations and should apply protections of the filtering unit and the fan. 

 

 

TECHNICAL  DATA 

Table No.1 

Type 
 

Maximum 

volume flow 

Maxi- 

mum 

vacuum 

Motor 

rate 

Supply 

voltage 

Quantity of 

cartridge 

filters 

Acoustic    
pressure 

level 

Compressed 

air 

consumption 

Weight 

 

[m

³/h] 

[Pa] 

[kW] 

[V/Hz] 

[pcs] 

[dB(A)] 

[Nm

3

/h] 

[kg] 

BIG-2000/Ex 

2900 

2600 

3x400/50 

67 

4,8 

550 

Cartridge filters:  quantity  2 pieces;   

diameter  

325 mm 

height  1000 mm 
total filtration area  48 m

2

 

 

Summary of Contents for BIG-2000/Ex

Page 1: ...ION 4 ASSEMBLY AND STARTUP 6 OPERATIONAL USE 8 TROUBLESHOOTING GUIDE 13 MAINTENANCE AND REPAIR 13 OCCUPATIONAL HEALTH AND SAFETY 14 TRANSPORT AND STORAGE 14 TERMS OF WARRANTY 15 DECLARATION OF CONFORM...

Page 2: ...s EN ISO 13857 2010 Safety of machinery Safe distances to prevent hazard zones from being reached by up per and lower limbs EN 60079 0 2013 03 A11 2014 03 Electrical appliances in areas of gas explosi...

Page 3: ...gressive impurities or of the air temperature exceeds 40 C what might result in damage of the filters 3 2 In the course of operational use it is important to prevent ignition sources i e sparks cigare...

Page 4: ...zones STRUCTURE ADN FUNCTION 5 1 Structure BIG 2000 Ex filtering unit consists of three functional assemblies Regeneration chamber being the upper part of the device where are located outlets from th...

Page 5: ...in details described in separate User s Manual In Fig No 3 is illustrated the filtering unit along with the fan chamber Connection between these two units is an example as applied in test station at t...

Page 6: ...ices and by a specialised assembly team First put the supporting structure with the hopper chamber The supporting frame should be levelled and its legs fastened firmly to the floor Having installed th...

Page 7: ...osion risk Especially here is important the hazard of explosion of fire with the purpose of selection of suitable protection sorts Any activities related to the installing necessarily must be performe...

Page 8: ...is designed to operate the filtering unit providing automatic regeneration of surfaces of the filters by means of cyclical impulses of compressed air The control system consists of subsequent assembl...

Page 9: ...Q1M motor protective switch F1 F2 overcurrent disconnectors T1 transformer K1 electromagnetic relay K1T K2T time relays K1M contactor PT resistance relay Fig No 10 Switchgear A1 control unit Fig No 1...

Page 10: ...om dP not active 0 01 9 99 kPa F13 control with the regeneration process 0 via contact 1 by readout from dP dP converter of the difference of pressures 7 2 1 Description of the displayed messages of t...

Page 11: ...of this function the display shows the dP readout and while the fan is stopped or the pipe conduits are not connected if the dP readout does not have the value 0 00 kPa this can be adjusted with pushb...

Page 12: ...y the red lamp H2 placed on the door of the switchgear A1 When the alarm occurs it is important to disconnect the power supply by means of the S1 disconnector Next find the fai lure damage find out it...

Page 13: ...he manufacturer in the instruction Filtration efficiency is too low Contact the manufacturer 3 Dust is appearing outside the The cartridge filter is damaged Replace the faulty element filtering unit a...

Page 14: ...d on the antistatic pad rug Near the device do not use mobile phone and other devices emitting electromagnetic waves The filtering unit cannot be submit to modification or complemented with functional...

Page 15: ...r device failures caused during the use which is in contradiction with the purpose of application and with the present Use and Maintenance Manual malfunctions resulting from the improper transport sto...

Page 16: ...of the European Parliament and of the Council of the 26 February 2014 on the harmo nisation of the laws of the Member States relating to the equipment and protective systems intended for use in potent...

Reviews: