Klimawent BIG-12000/Ex Use And Maintenance Manual Download Page 16

Klimawent

 – the warranty of highest quality at attractive price 

 

 

 

16 z 16 

Filtering unit

 

BIG-12000/Ex

 

10.10.2019 

 

 

TERMS  OF  WARRANTY 

The period  of  warranty   for  the  purchased device  

is

 indicated in the 

Card 

of 

Warranty

. The warranty does 

not comprise: 
● 

mechanical damage and malfunctions caused by User, 

● 

device failures  caused during the use  which is in contradiction with the purpose of application and with the 
present Use and Maintenance Manual, 

● 

malfunctions resulting from the improper transport, storage or incorrect maintenance. 

Infringement of the  Section 3 “Reservations of Producer”  of the  present  Use  and  Maintenance Manual  and, 
especially modifications  undertaken by User on one’s own or use in contradiction with the purpose of application  
–  shall result in the loss of warranty validity.

 

 

DECLARATION  OF  CONFORMITY 

 

 

DECLARATION  OF  CONFORMITY  EC  No

. _______________ 

Manufacturer  (eventually also the authorised representative / importer): 

name:

 

KLIMAWENT S.A.

 

address:

 

81-571 GDYNIA, ul. 

Chwaszczyńska 194

 

A person, authorised for issuing the technical documentation: 

name and address:

 Teodor 

Świrbutowicz, 

KLIMAWENT

 

S.A.

 

hereby declares that the product: 

Filtering unit

 

type / model:

 

BIG-12000/Ex

 

serial number:___________________ 

year of production: ___________________ 

 

Meets the requirements of the subsequent European Directives: 

2006/42/EC  Directive

 of  the  European  Parliament  and  of  the  Council  of  the  17  May,  2006  on  machinery, 

amending the 95/16/EC Directive (recast) / Official Journal EC L157 of the 09.06.2006, page 24); 

2014/35/EC Directive

 of the European Parliament and of the Council of the 26 February, 2014 on the harmo- 

nisation of the laws of the Member States, relating to the making available on the market of electrical equipment 
designed for use within certain voltage limits / Official Journal EC L96 of the 29.03.2014; 

2014/34/EC Directive

 of the European Parliament and of the Council of the 26 February, 2014 on the harmo- 

nisation of the laws of the Member States, relating to the equipment and protective systems intended for use in 
potentially explosive atmospheres / Official Journal EC L96 of the 29.03.2014 / 

1999/92/EC Directive of the Council

 of the 19 December, 1999 on minimum requirements regarding safety of 

health  protection  of  workers  employed  at  workplaces  where  explosive  atmosphere  is  likely  to  occur  /  Official 
Journal No.138, Pos. 931/ 

is in accordance with the requirements of the following harmonised standards: 

EN ISO-12100:2012

   

Safety of machinery 

– General principles of design – Assessment and reduction of hazard 

EN 60204-1:2010  

  Safety of machinery 

– Electrical equipment of machines  –  Part 1:  General requirements 

EN ISO 13857:2010    

Safety  of machinery 

– Safe distances to prevent hazard zones from being reached by 

up-per and lower limbs 

EN 60079-0:2013-03/A11:2014-03

   Electrical appliances in  areas of gas explosion hazard    - Part 0: General 

requirements 

EN 1127-1:2011  

Explosive atmospheres 

– Explosion prevention and protection.  Basic terminology and 

methodology 

EN ISO 80079-36:2016-07  

Explosive atmospheres 

– Part 36: Non-electrical appliances in areas of explosion 

risk Methodology and requirements 
 
 

 
 
 
 

 

 

 

 

place, date 

 

signature of the 

authorised person 

 

name, surname, 

function of the signatory 

 

 

Summary of Contents for BIG-12000/Ex

Page 1: ...URE ADN FUNCTION 4 ASSEMBLY AND STARTUP 5 OPERATIONAL USE 8 TROUBLESHOOTING GUIDE 14 MAINTENANCE AND REPAIR 14 OCCUPATIONAL HEALTH AND SAFETY 15 TRANSPORT AND STORAGE 15 TERMS OF WARRANTY 16 DECLARATI...

Page 2: ...afety of machinery Safe distances to prevent hazard zones from being reached by up per and lower limbs EN 60079 0 2013 03 A11 2014 03 Electrical appliances in areas of gas explosion hazard Part 0 Gene...

Page 3: ...es close to the filtering unit and in the vicinity 3 5 At the side of decompression panel it is important to create a hazard area of potential explosion according to the Fig No 5 This area should be f...

Page 4: ...losion Outside the chamber is installed a micro controller to activate the electromagnetic valves described in details in Section 7 Supporting construction along with the hopper chamber Underneath the...

Page 5: ...ng structure seal up the join surface with silicone and screw it up thoroughly with bolts The screws bolts and silicone are delivered by manufacturer along with the device The compressed air tank and...

Page 6: ...ing instructed Having completed the assembly check the conductivity between the subsequent parts of the device and check if the maximum resistance does not exceed 106 Ohm Grounding of the device and o...

Page 7: ...imawent the warranty of highest quality at attractive price 10 10 2019 Filtering unit BIG 12000 Ex 7 z 16 Fig No 6 Connection Diagram 1 3 Fig No 7 Connection Diagram 2 3 Fig No 8 Connection Diagram 3...

Page 8: ...control system Control unit is designed to operate the filtering unit providing automatic regeneration of surfaces of the filters by means of cyclical impulses of compressed air The control system co...

Page 9: ...The A3 terminal box connects the cable to the sensors on the venting panel with the output cable going out of the Switchgear A1 When the cable on the panel is interrupted during the explosion the devi...

Page 10: ...Klimawent the warranty of highest quality at attractive price 10 z 16 Filtering unit BIG 12000 Ex 10 10 2019...

Page 11: ...Klimawent the warranty of highest quality at attractive price 10 10 2019 Filtering unit BIG 12000 Ex 11 z 16...

Page 12: ...Klimawent the warranty of highest quality at attractive price 12 z 16 Filtering unit BIG 12000 Ex 10 10 2019...

Page 13: ...o controller controlling the function of the electromagnetic valves description in 7 2 These alarms are signalised by the red lamp H2 placed on the door of the switchgear A1 When the alarm occurs it i...

Page 14: ...s of ALARM during the function are described in Section 7 OPERATIONAL USE MAINTENANCE AND REPAIR 9 1 Cartridge filters It is necessary to undertake a visual control of the cartridge filters at any cas...

Page 15: ...ed with the contents of the present Use and Maintenance Manual For safety reasons the device must be connected to the power supply system strictly according to the enclosed Connection Diagram and with...

Page 16: ...6 page 24 2014 35 EC Directive of the European Parliament and of the Council of the 26 February 2014 on the harmo nisation of the laws of the Member States relating to the making available on the mark...

Reviews: