Filtering unit

 

BIG-12000/Ex

 

15 z 16 

 

 

Once for 2 

 3 months 

Overall visual control of the supporting construction 
(base frame) and of the housing. Examine the screw 
connections and anti-corrosion protection. 

Once for 12 months 

Check the state of the electrical connections and of the 
external installation of the compressed air, check the 
connections of the electromagnetic valves. 

Once for 12 

 18 months 

Visual control of the compressed air tank and of its 
dewaterer. When, (with reference to the environment 
and the state of the pressure air), it is necessary 

– this 

revision should be  executed more frequently. 

Fan 

– Use and Maintenance Manual of the fan 

Follow as according to the instruction 

Motor 

– Use and Maintenance Manual of the of the motor Follow as according to the instruction 

 

9.6  Measures of precaution during the revision activities and the maintenance 

 

Maintenance  and  revision  ought  to  be  executed  with  reference  to  the  being  valid  regulations, and 
with  the  present  Use  and  Maintenance  Manual  and  carried  out  by  authorised  workers  after  being 
instructed. 

 

Any activities on the device must be carried out after the fan is switched off and disconnected from 
the power supply mains. 

 

During these activities it is important to wear antistatic clothes. 

 

While  emptying  the  waste  container  of  the  dust,  during  the  dismantling  of  the  container  and  its 
mounting 

– the waste container must be placed on the antistatic pad / rug. 

 

Near the device, do not use mobile phone, and other devices emitting electromagnetic waves. 

 

The filtering unit cannot be submit to modification or complemented with functional parts or control 
elements, without the consent of the Deliverer.  

 

 

OCCUPATIONAL  HEALTH  AND SAFETY 

 

Assembly, installing, start-up and maintenance can be carried out after getting acquainted with the 
contents of the present Use and Maintenance Manual. 

 

For safety reasons, the device must be connected to the power supply system 

– strictly according 

to  the  enclosed  Connection  Diagram,    and  with  the  being  in  force  regulations  within  the  range  of 
personal protection against electric shock. 

 

Connection to the power supply system should be executed by an authorised person with electrical 
qualifications. 

 

Maximum operational pressure of the compressed air, for safety reasons, must not exceed 0,8 MPa. 

 

Any activities, connected with repair and technical revisions as well as emptying the filled up waste 
containers (underneath the hopper chamber) 

– should be executed after the fan is switched off and 

the device disconnected from the power supply. 

 

The fan as a rotating appliance 

– constitute a potential source of hazard, therefore installing, start up 

and maintenance should be carried out by qualified personnel. 

 

As the filtering unit is equipped with a decompression panel VMP 450x800 (0,34m

2

– the whole device 

should  be  placed  in  such  a  way,  that  there  is  provided  free  access  to  the  control  system,  and 
additionally, (in case of explosion) there should be safety area for the discarded vent panel.  During 
the explosion, the control connection shall be interrupted and the filtering unit stops functioning. 

 

 

TRANSPORT   AND  STORAGE 

The filtration body (along with the cartridge filters) and the regeneration chamber with the compressed air tank 
and  electromagnetic  valves  are  integrated  together  with  screw  connections.  The  second  assembly  is  the  self-
discharging hopper with the supporting structure. 
BIG-12000/Ex filtering unit is transported in two assemblies, wrapped in foil, placed on transport pallets.  During 
the time of transport, the assemblies must be located vertically and protected from overturn (being knocked down) 
and from displacement.  
Handle with care during the lifting the subsequent assemblies, during the transport, unloading and mounting. The 
device has to be stored in close rooms and in dry rooms and in areas of efficient ventilation. 
 

 

Summary of Contents for BIG-12000/Ex

Page 1: ...URE ADN FUNCTION 4 ASSEMBLY AND STARTUP 5 OPERATIONAL USE 8 TROUBLESHOOTING GUIDE 14 MAINTENANCE AND REPAIR 14 OCCUPATIONAL HEALTH AND SAFETY 15 TRANSPORT AND STORAGE 15 TERMS OF WARRANTY 16 DECLARATI...

Page 2: ...afety of machinery Safe distances to prevent hazard zones from being reached by up per and lower limbs EN 60079 0 2013 03 A11 2014 03 Electrical appliances in areas of gas explosion hazard Part 0 Gene...

Page 3: ...es close to the filtering unit and in the vicinity 3 5 At the side of decompression panel it is important to create a hazard area of potential explosion according to the Fig No 5 This area should be f...

Page 4: ...losion Outside the chamber is installed a micro controller to activate the electromagnetic valves described in details in Section 7 Supporting construction along with the hopper chamber Underneath the...

Page 5: ...ng structure seal up the join surface with silicone and screw it up thoroughly with bolts The screws bolts and silicone are delivered by manufacturer along with the device The compressed air tank and...

Page 6: ...ing instructed Having completed the assembly check the conductivity between the subsequent parts of the device and check if the maximum resistance does not exceed 106 Ohm Grounding of the device and o...

Page 7: ...imawent the warranty of highest quality at attractive price 10 10 2019 Filtering unit BIG 12000 Ex 7 z 16 Fig No 6 Connection Diagram 1 3 Fig No 7 Connection Diagram 2 3 Fig No 8 Connection Diagram 3...

Page 8: ...control system Control unit is designed to operate the filtering unit providing automatic regeneration of surfaces of the filters by means of cyclical impulses of compressed air The control system co...

Page 9: ...The A3 terminal box connects the cable to the sensors on the venting panel with the output cable going out of the Switchgear A1 When the cable on the panel is interrupted during the explosion the devi...

Page 10: ...Klimawent the warranty of highest quality at attractive price 10 z 16 Filtering unit BIG 12000 Ex 10 10 2019...

Page 11: ...Klimawent the warranty of highest quality at attractive price 10 10 2019 Filtering unit BIG 12000 Ex 11 z 16...

Page 12: ...Klimawent the warranty of highest quality at attractive price 12 z 16 Filtering unit BIG 12000 Ex 10 10 2019...

Page 13: ...o controller controlling the function of the electromagnetic valves description in 7 2 These alarms are signalised by the red lamp H2 placed on the door of the switchgear A1 When the alarm occurs it i...

Page 14: ...s of ALARM during the function are described in Section 7 OPERATIONAL USE MAINTENANCE AND REPAIR 9 1 Cartridge filters It is necessary to undertake a visual control of the cartridge filters at any cas...

Page 15: ...ed with the contents of the present Use and Maintenance Manual For safety reasons the device must be connected to the power supply system strictly according to the enclosed Connection Diagram and with...

Page 16: ...6 page 24 2014 35 EC Directive of the European Parliament and of the Council of the 26 February 2014 on the harmo nisation of the laws of the Member States relating to the making available on the mark...

Reviews: