Filtering unit
BIG-12000/Ex
15 z 16
Once for 2
3 months
Overall visual control of the supporting construction
(base frame) and of the housing. Examine the screw
connections and anti-corrosion protection.
Once for 12 months
Check the state of the electrical connections and of the
external installation of the compressed air, check the
connections of the electromagnetic valves.
Once for 12
18 months
Visual control of the compressed air tank and of its
dewaterer. When, (with reference to the environment
and the state of the pressure air), it is necessary
– this
revision should be executed more frequently.
Fan
– Use and Maintenance Manual of the fan
Follow as according to the instruction
Motor
– Use and Maintenance Manual of the of the motor Follow as according to the instruction
9.6 Measures of precaution during the revision activities and the maintenance
Maintenance and revision ought to be executed with reference to the being valid regulations, and
with the present Use and Maintenance Manual and carried out by authorised workers after being
instructed.
Any activities on the device must be carried out after the fan is switched off and disconnected from
the power supply mains.
During these activities it is important to wear antistatic clothes.
While emptying the waste container of the dust, during the dismantling of the container and its
mounting
– the waste container must be placed on the antistatic pad / rug.
Near the device, do not use mobile phone, and other devices emitting electromagnetic waves.
The filtering unit cannot be submit to modification or complemented with functional parts or control
elements, without the consent of the Deliverer.
OCCUPATIONAL HEALTH AND SAFETY
Assembly, installing, start-up and maintenance can be carried out after getting acquainted with the
contents of the present Use and Maintenance Manual.
For safety reasons, the device must be connected to the power supply system
– strictly according
to the enclosed Connection Diagram, and with the being in force regulations within the range of
personal protection against electric shock.
Connection to the power supply system should be executed by an authorised person with electrical
qualifications.
Maximum operational pressure of the compressed air, for safety reasons, must not exceed 0,8 MPa.
Any activities, connected with repair and technical revisions as well as emptying the filled up waste
containers (underneath the hopper chamber)
– should be executed after the fan is switched off and
the device disconnected from the power supply.
The fan as a rotating appliance
– constitute a potential source of hazard, therefore installing, start up
and maintenance should be carried out by qualified personnel.
As the filtering unit is equipped with a decompression panel VMP 450x800 (0,34m
2
)
– the whole device
should be placed in such a way, that there is provided free access to the control system, and
additionally, (in case of explosion) there should be safety area for the discarded vent panel. During
the explosion, the control connection shall be interrupted and the filtering unit stops functioning.
TRANSPORT AND STORAGE
The filtration body (along with the cartridge filters) and the regeneration chamber with the compressed air tank
and electromagnetic valves are integrated together with screw connections. The second assembly is the self-
discharging hopper with the supporting structure.
BIG-12000/Ex filtering unit is transported in two assemblies, wrapped in foil, placed on transport pallets. During
the time of transport, the assemblies must be located vertically and protected from overturn (being knocked down)
and from displacement.
Handle with care during the lifting the subsequent assemblies, during the transport, unloading and mounting. The
device has to be stored in close rooms and in dry rooms and in areas of efficient ventilation.