Klimawent 808W18 Use And Maintenance Manual Download Page 15

 

 15 

 

 

 

 

04.06.2019                                

chem-proof Ex roof fan

  SPARK-CHEM/Ex  

 

 
 

14.  Sample of the Declaration of Conformity 

 

 

 

Declaration of conformity EC No. …………….. 

 

Manufacturer (eventually the authorized representative / importer): 
name:  

KLIMAWENT  S.A.

 

address:  

81-571 Gdynia,  

Chwaszczyńska 194

  

 

A person, authorized for issuing the technical documentation:  

Teodor Świrbutowicz,  KLIMAWENT S.A. 

 

hereby declares that the appliance: 
name:   

chem-proof Ex roof fans

 

 

type/model: 

SPARK-CHEM/Ex

 

serial number:  ……………………………..  year of production:  ……………………….. 

 

meets the requirements of the subsequent European Directives:

 

 

 

2006/42/EC

 

Machinery Directive 

of the European Parliament and of the Council of May 17

th

, 2006  on machinery 

– amen- 

ding the 95/16/EC (recast) /

Journal of Laws EC L157 of 09.06.2006, page 24

 

 

 

2014/35/EC Directive  

of the European Parliament  and  of the Council of February 26

th

, 2014  on the harmonisation of the  

laws of  the Member States  relating to the making available  on the market of electrical equipment  designed for use within  
certain voltage limits.  /

Journal of Laws EC L96  of 29.03.2014

/

 

 

 

 

2014/34/EC ATEX Directive 

of the European Parliament and of the Council of February 26

th

, 2014 on the harmonisation of  

the laws of Member States relating to equipment and protective systems intended for use in potentially explosive atmosphe- 
res. / 

Journal of Laws EC L96  of 29.03.2014

 / 

 

The appliance meets following harmonized standard: 

 

● 

EN ISO-12100:2012 

 
 

 

“Safety of machinery – Basic concepts, general principles for design. Ha- 

 

 

 

zard 

assessment and risk reduction”. 

 

 

 

 

● 

EN 60204-1:2018-12 

 
 

 

“Safety of machinery   

 Electrical equipment of machines.  Part 1: Gene- 

 

 

 

ral 

requirements”. 

 

 

 

 

● 

EN ISO 13857:2010 

 
 

 

“Safety of machinery   

 Safe distances to prevent hazard zones from be- 

 

 

 

ing 

reached by upper and lower limbs”. 

 

 

 

 

● 

EN 80079-0:2013/A11:2014 

 
 

 

“Electrical 

appliances 

in areas of gas explosion risk.

   

Part 0: General re- 

 

 

 

quirements”. 

 

 

 

 

● 

EN 60079-7:2016-02 

 
 

 

“Electrical

 

appliances

 

for areas

 

of gas explosion hazard. Part 7: Increased

 

 

 

 

safety construction “

e

”. 

 

 

 

 

● 

EN 1127-1:2011 

 
 

 

“Explosive atmospheres – Explosion prevention and protection. Basic ter- 

 

 

 

minology 

and methodology”. 

 

 

 

 

● 

EN ISO 80079-36:2016-07 

 
 

 

“Explosive atmospheres  – Part 36:  Non-electrical equipment for explosi- 

 

 

 

ve atmospheres.  Methodology and requirements.  

 

 

 

 

● 

EN ISO 80079-37:2016-07 

 
 

 

“Explosive atmospheres  – Part 37:  Non-electrical equipment for explosi- 

 

 

 

ve atmospheres. Non-electrical types of protection.

  

Constructional safety 

c

”, supervised ignition “

b

”, immersion in a liquid “

k

”. 

 

 

 

 

● 

EN 14986:2017-02 

 
 

 

“Designing of fans applied in areas of explosion hazard” 

 

 

 

 

● 

ISO 14694:2003+AMD1:2010 

 
 

 

“Industrial fans

   

– Guidelines on the quality of balancing and the vibration 

 

 

 

level. 

 

 

 

 

● 

ISO 14695:2008/AC:2017-10 

 
 

 

“Industrial fans  – Methods of measurements of vibration of fans. 

 

…………………………… 

…………………………… 

…………………………… 

place, date 

signature of authorised person 

name, surname, function 

 

 

of the signatory 

 

KLIMAWENT  S.A. 

District Court Gdańsk-Północ 

NIP:  958 159 21 35 

Supported Employment Enterprise 

in Gdańsk,  VII Wydział Gospodarczy  REGON:  220631262 

81-571 Gdynia, 

ul. Chwaszczyńska 194

 

of the National Register of Court 

Bank Account:  

Santander Bank Polska S.A. 

phone: +49 58 829 64 80 

KRS 0000308902  company stock 

56 1500 1025 1210  2007 8845 0000 

email:  

[email protected]

  13.779.200 zł paid in total 

 

Summary of Contents for 808W18

Page 1: ...nction 5 6 Assembly and Start up 6 7 Operational Use 8 8 Troubleshooting Guide 8 9 Maintenance 8 10 Occupational Health and Safety 9 11 Transport and Storage 9 12 Terms of warranty 10 13 Table of resistance of PVC against various substances 11 14 Sample of the Declaration of Conformity 15 808W18 SPARK CHEM 160 1500 Ex 04 06 2019 EN 808W19 SPARK CHEM 200 1500 Ex 04 06 2019 EN 808W20 SPARK CHEM 250 ...

Page 2: ...of the Council of February 26th 2014 on the harmonisation of the laws of Member States relating to equipment and protective systems intended for use in potentially explosive atmospheres Journal of Laws EC L96 of 29 03 2014 Additionally the appliance meets following harmonized standard EN ISO 12100 2012 Safety of machinery Basic concepts general principles for design Risk assessment and risk reduct...

Page 3: ...gory 2 the device is designed for application in areas where explosive atmosphe res are likely to occur gas hazard G c refers the protection from ignition constructional protection b protection by means of controlling the ignition sources Ex mark of the electrical device constructed and tested according to the European Stan dards for work in areas of explosion hazard execution e type of constructi...

Page 4: ...nical Data Table No 1 Type of the fan Synchro nous rotations 1 min Supply voltage V Motor rate kW Maximum volume flow m3 h Maximum vacuum Pa Acoustic pressure level from distance Weight kg 1 m 5 m dB A SPARK CHEM 160 1500 Ex 1500 3 x 400 0 12 670 110 57 48 10 6 SPARK CHEM 200 1500 Ex 1500 3 x 400 0 18 1330 180 59 50 14 2 SPARK CHEM 250 1500 Ex 1500 3 x 400 0 37 2500 280 66 57 18 3 SPARK CHEM 315 1...

Page 5: ...x 315 339 660 622 8 7 5 Structure and Function Structure of the fan is illustrated on Fig No 3 The subsequent constructional elements of the fan except the impeller are of antistatic plastic PE EL The impeller is made of stainless steel therefore it is possible to forward the chemically aggressive and flammable gases and vapours as a mixture with the air In the course of constructing there were se...

Page 6: ...n inlet is protected with perforated plate that no external objects debris would not get into the impeller space On demand we deliver isolating switches safety switches to cut off the power supply during the installing and servicing activities see catalogue card Electrical Accessories 6 Assembly and Start up Prior to installing examine the delivered fan for damages and impurities occurred during t...

Page 7: ... power supply system strictly according to the Connec tion Diagram located in the inner side of the terminal box cover 6 2 Safety inspection before the start up a Examine if all the mechanical connections are performed correctly b Examine the correctness of the electrical connections phases sequence c Check the correctness of the connection of the motor and the fan housing with the PE pro tective ...

Page 8: ...spare part replacement according to ATEX 2014 34 Directive it is important to apply the adequate information on an additional plate or in the enclosed documentation a register log of repair activities etc This is the duty of User A list of most frequent functional malfunctions and their corrective measures is listed below 8 Troubleshooting Guide Table No 3 Problem Possible reason Corrective action...

Page 9: ...e operational use of the fan are admissible after getting acquainted with the contents of the present Use and Maintenance Manual The fan shall not cause any ha zard under the condition it is correctly and firmly installed within the ventilation system or to the supporting structure Any installation activities related to the power supply system have to be carried out strictly ac cording to the encl...

Page 10: ... use which was in contradiction with the purpose of opera tional use and with the present Use and Maintenance Manual any damages being caused during improper transport storage or incorrect maintenance Infringement of the Clause G Section 3 Reservations of Producer of the present Use and Maintenance Manual and especially modifications undertaken by User on one s own or use in contradiction with the...

Page 11: ...ol butyl alcohol 100 o Liquid chlorine 100 Dry gaseous chlorine 100 Potassium chlorate 7 3 o Sodium chlorate aqueous solution 25 Ammonium chloride aqueous solution all Zinc chloride Ethylene chloride 100 Methyl chloride 100 Potassium chloride aqueous solution saturated Sodium chloride domestic salt aqueous solution saturated Sodium chloride aqueous solution 5 Chlorobenzene 100 Cadmium cyanide Copp...

Page 12: ... Acetic acid icy 100 o Acetic acid aqueous solution 50 Oleic acid 100 o Sulphuric acid 3 50 96 o Sulphuric acid 50 10 Hydrochloric acid 35 Stearic acid 100 Oxalic acid saturated Acidic sodium carbonate aqueous solution saturated Acidic sodium sulphate aqueous solution saturated Nail lacquer o Lysol White liquor 12 5 of the active chlorine o Potassium lye 10 50 Potassium permanganate aqueous soluti...

Page 13: ...oda Vapours of tio urea Vapours of aliphatic hydrocarbons Gaseous ozone Automotive fuel normal petrol Automotive fuel petrol super Automotive fuel diesel oil Paraffin 100 Beer Brake fluid Anti freeze fluid di ethylene glycol Sodium hypochlorite aqueous solution 5 Liquid propane 100 Cresol solution Soap solution saturated Mercury 100 Rum 40 Potassium sulphate aqueous solution saturated Sodium sulph...

Page 14: ...sium carbonate aqueous solution saturated Sodium carbonate aqueous solution saturated Water 100 Chlorinated water saturated Aqua regia nitro hydrochloric acid Seawater Sodium hydroxide 50 Sodium hydroxide caustic soda 100 resistant conditionally resistant with the occurrence hazard of tensioning stress cracks 0 conditionally resistant low resistant not resistant ...

Page 15: ... reduction EN 60204 1 2018 12 Safety of machinery Electrical equipment of machines Part 1 Gene ral requirements EN ISO 13857 2010 Safety of machinery Safe distances to prevent hazard zones from be ing reached by upper and lower limbs EN 80079 0 2013 A11 2014 Electrical appliances in areas of gas explosion risk Part 0 General re quirements EN 60079 7 2016 02 Electrical appliances for areas of gas e...

Page 16: ...16 chem proof Ex roof fan SPARK CHEM Ex 04 06 2019 www klimawent com pl NOTES ...