13
05.11.2019
cyclone separator
STORM-H
-{
1000
;
2000
;
5000
}
EMPTYING OF THE WASTE CONTAINER
1
.
The container is equipped with a swinging discharge bottom, protected with a clasp mecha-
nism on both sides of the bottom.
2
.
Transport the waste container (with a forklift) above a larger collective container, then open
the bottom cover (release the locking hooks). Take precaution while dumping
– the unloa-
ding mass would cause a sudden bottom cover drop.
3
.
Having emptied and cleaned the waste container, shut the bottom cover and close its hook
fastenings (of the bottom cover).
4
.
Transport the waste container back and install it underneath the cyclone separator.
8. Troubleshooting Guide
Table No.4
Problem
Possible reason
Corrective action
1.
Sudden drop in the suction Objects, impurities, causing Clean the inlet grill
volume flow.
obstacle to the air flow,
and remove the clogging
got stuck at the inlet grill.
objects.
2.
Abrupt vibration of the fan Clogging objects, causing
Disconnect the fan from
occur.
obstacle to the air flow,
the power supply and
got stuck at the impeller.
remove the object.
The impeller is faulty.
Replace the impeller and
the motor for new.
3.
Cleaning efficiency
Ventilation ducting got
Replace the ventilation
of the dust laden air
damaged.
ducting for new.
is decreasing.
The waste container
Empty the waste container
is overloaded (over-filled).
(see Fig. No.7).
9. Maintenance
The construction provides long-lasting and efficient work without routing technical supervision.
In the course
of operational use
, simply it is sufficient to control the systematic waste container
emptying.
Examine the
mechanical efficiency
of connections
with the devices of local exhausts.
After a year of use, the fan ought to be submit to a detailed technical supervision. Additionally,
the fan motor is subject to technical revision, according to the instructions of the motor manu-
facturer.
10. Occupational Health and Safety
Startup and operational use are possible after getting acquainted with the present Use
and Maintenance Manual
.
The use is easy and safe
and do not cause
hazard to operators. Manufacturer is not responsi-
ble for effects caused during the incorrect use, in contradiction to the purpose of application.
The
cyclone separator ought
to be fastened to the floor by means of four foundation bolts
M16
.
Any activity related to connection to the power supply system should be carried out according
to the instructions of Section 6 of the present User’s Manual. This must be executed by an au-
thorized person with qualification (according to the valid regulations).
The fan motor ought to
be protected against
short-circuit- and overload effects. During the use,
examine connection between the fan and the PE protective cable.
The appliance
meets the safety requirements
of the Machinery Directive 2006/42/EN and
do not require any additional means of protection for a safe use.