cyclone separator

  STORM-H

-{

1000

;

 2000

;

 5000

}

 

 

 

EMPTYING  OF  THE  WASTE  CONTAINER

 

1

.

 

The container is equipped with a swinging discharge bottom, protected with a clasp mecha-
nism on both sides of the bottom. 

2

.

 

Transport the waste container (with a forklift) above a larger collective container, then open 
the bottom cover (release the locking hooks).  Take precaution while dumping  

–  the unloa-

ding mass would cause a sudden bottom cover drop. 

3

.

 

Having emptied and cleaned the waste container, shut the bottom cover and close its hook 
fastenings (of the bottom cover). 

4

.

 

Transport the waste container back and install it underneath the cyclone separator. 

 

8.  Troubleshooting Guide 

Table No.4 

 

Problem 

Possible reason 

Corrective action  

1. 

Sudden drop in the suction  Objects, impurities, causing   Clean the inlet grill 

 

volume flow. 

obstacle to the air flow, 

and remove the clogging 

 

 

got stuck at the inlet grill. 

objects. 

2. 

Abrupt vibration of the fan   Clogging objects, causing  

Disconnect the fan from 

 

occur. 

obstacle to the air flow, 

the power supply and  

 

 

got stuck at the impeller. 

remove the object. 

 

 

The impeller is faulty. 

Replace the impeller and  

 

 

 

the motor for new. 

3. 

Cleaning efficiency 

Ventilation ducting got 

Replace the ventilation 

 

of the dust laden air 

damaged. 

ducting for new. 

 

is decreasing. 

The waste container  

Empty the waste container 

 

 

is overloaded (over-filled). 

(see Fig. No.7). 

 

9.  Maintenance 

The construction provides long-lasting and efficient work without routing technical supervision. 
In the course 

of operational use

, simply it is sufficient to control the systematic waste container 

emptying. 

Examine the

 mechanical efficiency 

of connections

 with the devices of local exhausts. 

 

After a year of use, the fan ought to be submit to a detailed technical supervision. Additionally, 
the fan motor is subject to technical revision,  according to the instructions of the motor manu-
facturer. 
 

10.  Occupational Health and Safety 

Startup and operational use are possible after getting acquainted with the present Use  
and Maintenance Manual

The use is easy and safe 

and do not cause 

hazard to operators. Manufacturer is not responsi- 

ble for effects caused  during the incorrect use,  in contradiction to the purpose of application. 
The 

cyclone separator ought

 to be fastened to the floor by means of four foundation bolts 

M16

Any activity related to connection to the power supply system should be carried out according  
to the instructions of Section 6 of the present User’s Manual. This must be executed by an au-
thorized person with qualification (according to the valid regulations). 
The fan motor ought to 

be protected against

 short-circuit- and overload effects. During the use, 

examine connection between the fan and the PE protective cable. 

The appliance 

meets the safety requirements

 of the Machinery Directive 2006/42/EN and 

do not require any additional means of protection for a safe use. 

 

 

Summary of Contents for 802O14

Page 1: ...3 40 802O14 STORM 1000 SOFT H 05 11 2019 EN e mail klimawent klimawent com pl 802O15 STORM 2000 SOFT H 05 11 2019 EN www klimawent com pl 802O16 STORM 5000 SOFT H 05 11 2019 EN Contents 1 Introductory...

Page 2: ...ropean Parliament and of the Council with regard to ecodesign requirements for fans driven by motors with an electric input power between 125W and 500 kW Journal of Laws L No 90 of 06 04 2011 Addition...

Page 3: ...maximum impeller rotations should not exceed nominal rotations I In the course of operational use pay attention that any ignition sources i e glowing cigarettebutts embers should not get into cyclone...

Page 4: ...4 cyclone separator STORM H 1000 2000 5000 05 11 2019 STORM 1000 SOFT H STORM 2000 H...

Page 5: ...5 05 11 2019 cyclone separator STORM H 1000 2000 5000 STORM 2000 SOFT H STORM 5000 H...

Page 6: ...version STORM SOFT H 6 sound absorbing set for version STORM H on separate order 7 motor protective switch for versions STORM 1000 H STORM 2000 H or motor starter for version STORM 5000 H The dust se...

Page 7: ...7 05 11 2019 cyclone separator STORM H 1000 2000 5000 Fig No 1 STORM H and STORM SOFT H Structure...

Page 8: ...8 cyclone separator STORM H 1000 2000 5000 05 11 2019 STORM 1000 H STORM 2000 H STORM 5000 H Fig No 2 STORM H Dimensions...

Page 9: ...9 05 11 2019 cyclone separator STORM H 1000 2000 5000 STORM 1000SOFT H STORM 2000 SOFT H STORM 5000 SOFT H Fig No 3 STORM SOFT H Dimensions...

Page 10: ...industrial rooms They can be also used outside the building but with additional protection against atmospheric factors weather conditions i e roofing The separator must be placed stably on the even fl...

Page 11: ...tion where the cyclone separator serves as a final filter the fan outlet ought to be equipped with a sound absorbing set delivery on separate order Whereas when the cyclone works as a pre filter it is...

Page 12: ...itoring When the waste container is filled up switch off the device and empty the container according to the instructions on pages 12 14 Having cleaned the con tainer put it underneath the cyclone sep...

Page 13: ...aded over filled see Fig No 7 9 Maintenance The construction provides long lasting and efficient work without routing technical supervision In the course of operational use simply it is sufficient to...

Page 14: ...ventilation 12 Terms of warranty The period of warranty for the purchased device is indicated in the Card of Warranty The warranty does not comprise mechanical damage and malfunctions caused by User...

Page 15: ...of October 21th 2009 establishing a framework for the setting of ecodesign requirements for energy related products Journal of Laws L 285 of 31 10 2009 327 2011 EU Guideline of March 30th 2011 on imp...

Page 16: ...16 cyclone separator STORM H 1000 2000 5000 05 11 2019 NOTES...

Reviews: