60
10.1.7How to Remove the Fan motor
Step1:
The chassis is hold by the installation plate
and two snap-fit designs. Hold out against
the A and B with two index fingers, and pull
it away from the installation plate along the
direction indicated in right image about 25
degree.
Step2:
Disconnect the copper pipe to remove the
unit form wall. Remove the panel, filter,
electric cover, display box ,louver, electric
control box and frame part according to
the previous steps.
Step3:
Unfold the Pipe clamp locker A and B
along the direction indicated in right image.
Summary of Contents for KSIF009-H115-I